R2W PLUS
30
4.4 Distance measurement mode
4.4.1 Distance measurement and measuring mode setting
Operation steps
Keys
Display
①
Collimate the center of
prism.
Collimate
②
Click “M.Dist” key to
enter distance measurement
mode, and then the system
will carry out measurement
based on previous setting
mode.
【
M.Dist
】
③
Click “Mode” key to
activate setting function of
distance measurement mode.
Take
“Loop
Fine”
as
example here.
Fine
: single fine measuring
mode
N Fine:
n times fine
measuring mode
Loop Fine
: Continuous
measuring mode
Track
: tracking measuring
mode
【
Mode
】