Initial Configuration
21
If the Automatic Configuration Fails
• If the automatic configuration fails, and you do not have a display
connected, you can check for the reason in the log
(
sg_autoconfig.log
) written on the USB stick.
• If you see a “connection refused” error message, ensure that the
Management Server IP address is reachable from the engine and
check the IP addresses you have defined in the Management Client.
• If the configuration with the USB stick still does not succeed, follow
the instructions for the manual configuration, see
Configuring the
Engine with Configuration Wizard
below.
Configuring the Engine with Configuration Wizard
T
To start the configuration wizard
¬
Turn on the appliance using the power on/off button. The engine
bootup process is shown in the console and, after some time,
the engine configuration wizard starts.
T
To select the configuration method
1.
Do one of the following:
•
To import a saved configuration, highlight
Import
using the arrow
keys and press E
NTER
.
•
To skip the import, highlight
Next
and press E
NTER
.
2.
If you selected the Import option, select the configuration file.
T
To set the keyboard layout
1.
Highlight the entry field for
Keyboard Layout
using the arrow keys
and press E
NTER
. The Select Keyboard Layout dialog opens.
2.
Highlight the correct layout and press E
NTER
.
Note –
You can (re)start the engine configuration wizard at any time
using the
sg-reconfigure
command on the engine command line.
1