11
GB
Product information ErP
R40
Product information about the directive 2009/125/EG and regulation (EU) 813/2013
R40
Icon
Unit
45/50
65
85
100
120
150
Condensing boiler
-
-
Yes
Yes
Yes
Yes
Yes
Yes
Low-temperature boiler
-
-
No
No
No
No
No
No
B1 boiler
-
-
No
No
No
No
No
No
Cogeneration space heater
-
-
No
No
No
No
No
No
Combination heater
-
-
No
No
No
No
No
No
ErP Heating
Rated heat boiler
P
rated
kW
46
61
81
93
112
132
At rated heat output and high-tempera-
ture regime
P4
kW
45.7
60.8
81.1
92.9
111.6
132.2
At 30 % of rated heat output and
lowtemperature regime 1)
P1
kW
15.1
20.0
26.8
30.6
36.7
43.5
Seasonal space heating energy effi-
ciency
K
s
%
92
92
92
92
92
92
At rated heat output and high-temperatu-
re regime 2)
K
4
%
87.7
87.7
87.7
87.9
87.9
87.9
At 30 % of rated heat output and low
temperature regime 1)
K
1
%
96.5
96.5
96.5
96.5
96.5
96.5
Auxiliary electricity consumption
At full load
elmax
kW
0.100
0.100
0.214
0.214
0.214
0.221
At rated heat output and high-tempera-
ture regime
elmin
kW
0.025
0.025
0.038
0.038
0.038
0.043
At 30 % of rated heat output and
lowtemperature regime 1)
P
SB
kW
0.003
0.003
0.003
0.003
0.003
0.003
Supplementary heater
Standby heat loss
P
stby
kW
0.122
0.122
0.122
0.122
0.122
0.122
Ignition burner power consumption
P
ign
kW
0.000
0.000
0.000
0.000
0.000
0.000
Emissions of nitrogen oxides
NO
X
mg/kWh
39
39
39
39
39
39
1) by return temperature 30°C
2) by return temperature and feed temperature (60-80°C)