background image

13

29. 

Press the SEL button. The LCD will read “CutOut 
amps” along with the programmed value from the 
previous step. 

30. 

Press the SEL button three times. The LCD will 
read “EXITMENU”.

31. 

Press the up arrow (

) button to exit the menu.

32. 

Adjustment to the control is completed.

E. SERVING PRODUCT

33. 

Place the Freezing Cylinder OFF/ON switch in 
the ON position.

34. 

Press the PUSH TO FREEZE button.

35. 

When the product is at 75% consistency, the 
display will read “SERVE”.

36. 

For normal dispensing, move the spigot handle 
fully open.

37. 

The machine dispenses product at a reasonable 
draw rate. If the machine is overdrawn, the result 
is a soft product or a product that will not dispense 
at all. If this occurs, allow the machine to run for 
approximately 30 seconds before dispensing more 
product. A dispense rate adjustor is located under 
the header panel, to the immediate right of the 
spigot handle. Turning the knob counterclockwise 
will decrease the dispense rate.

38. 

Do not operate the machine when the MIX LOW 
message is displayed. Refi ll the mix container 
immediately.

NOTE

The machine has a standby and sleep mode. After 
a preset number of freezing cycles, it will enter the 
standby mode (followed by sleep mode) and remain 
there until someone draws product or presses the 
PUSH TO FREEZE button. In the sleep mode, the 
machine will keep the product below 41°F (5°C). 
Sleep modes do not take the place of cleaning 
and sanitizing. Federal, State, and local regulatory 
agencies determine frequency of cleaning and 
sanitizing.

3.10 NORMAL FREEZE DOWN AND 
OPERATION

The following section contains the recommended oper-
ating procedures for the safe operation of the machine.

A. 

Sanitize immediately before use.

B. 

Make sure the Freezing Cylinder Off/On switch 
is in the OFF position.

C. 

Fill the storage container in the cab with at least 
2.5 gallons of mix.

D. 

Attach the mix inlet probe to the container and 
place the container in the refrigerated cab.

E. 

Place the mix pump switch in the ON position.

F. 

Place a container under the spigot and open the 
spigot to allow the mix to fl ush out about 8 ounces 
(0.23 liters) of sanitizing solution and liquid mix.

G. 

Open the air bleed valve on the front door by 
pressing and holding. Hold the valve open until 
the mix level in the freezing cylinder is 1/2” from 
the air bleed valve.

H. 

Place the Freezing Cylinder OFF/ON switch in 
the ON position.

I. 

Press the PUSH TO FREEZE button.

NOTE

After the drive motor starts, there is a 3-second 
delay before the compressor starts.

J. 

When the product is at 75% consistency, the 
display will read “SERVE”. Open the spigot to 
dispense product.

K. 

The machine dispenses product at a reasonable 
draw rate. If the machine is overdrawn, the result 
is a soft product or a product that will not dispense 
at all. If this occurs, allow the machine to run for 
approximately 30 seconds before dispensing more 
product. A dispense rate adjustor is located under 
the header panel, to the immediate right of the 
spigot handle. Turning the knob counterclockwise 
will decrease the dispense rate.

M. 

Do not operate the machine when the MIX LOW 
message is displayed. Refi ll the mix container 
immediately.

NOTE

The machine has a standby and sleep mode. After 
a preset number of freezing cycles, it will enter the 
standby mode (followed by sleep mode) and remain 
there until someone draws product or presses the 
PUSH TO FREEZE button. In the sleep mode, the 
machine will keep the product below 41°F (5°C). 
Sleep modes do not take the place of cleaning 
and sanitizing. Federal, State, and local regulatory 
agencies determine frequency of cleaning and 
sanitizing.

3.11 MIX INFORMATION

Mix can vary considerably from one manufacturer to 
another. Differences in the amount of butterfat content 
and quantity and quality of other ingredients have a 
direct bearing on the fi nished frozen product. A change 
in machine performance that cannot be explained by a 
technical problem may be related to the mix.

Proper product serving temperature varies from one 
manufacturer’s mix to another. Mixes should provide a 
satisfactory product in the 20°F to 24°F range. Diet and 
low-carb mixes typically freeze to proper consistency at 
higher temperatures.

When checking the temperature, stir the thermometer in 
the frozen product to get an accurate reading.

Summary of Contents for O411

Page 1: ...Model O411 OPERATORS MANUAL Manual No 513626 Rev 3...

Page 2: ......

Page 3: ...built prior to date of change DO NOT ATTEMPT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood If problems develop or q...

Page 4: ...ecific safety information the following safety defini tions are provided to assist the reader The purpose of safety symbols is to attract your at tention to possible dangers The safety symbols and the...

Page 5: ...ting Controls and Indicators 7 3 3 Disassembly of Machine Parts 9 A Disassembly of Front Door 9 B Disassembly of Auger 9 3 4 Cleaning Disassembled Parts 10 3 5 Sanitizing Machine Parts 10 3 6 Cleaning...

Page 6: ...8 Overrun Adjustment 20 4 9 Mix Pump Hose Reposition 21 4 10 Mix Pump Hose Replacement 21 4 11 Cab Temperature Adjustment 22 4 12 Drive Belt Tension Adjustment 22 4 13 Condenser Cleaning Air Cooled M...

Page 7: ...o operate with almost any type of commercial soft serve or non dairy mixes available including ice milk ice cream yogurt and frozen dietary desserts This manual is designed to assist qualified service...

Page 8: ...hase 208 240 VAC 60Hz running amps 15A connection type NEMA6 20P power cord provided Compressor 13 000 Btu hr Scroll Compressor Drive Motor 3 4 hp Air Flow Air cooled units require 3 7 6 cm air space...

Page 9: ...lation must be completed by a qualified electrician refrigeration specialist Incorrect installation may cause personal injury severe damage to the machine and will void fac tory warranty Installation...

Page 10: ...hose clamp Be careful not to twist the mix hose 7 Turn the pump on 8 Allow the remaining 6 15cm of tubing to feed through pump until the hose adapter prevents further feeding 9 Turn the pump off CAUTI...

Page 11: ...d nearest the outlet of the manifold will drain last and should be placed at the back of the mix container The mix low level indicator relies on proper bag placement 1 Connect3 8 9 5mm IDplasticfoodgr...

Page 12: ...mp 3 Push the manifold adapter with spring and valve into the left port nearest the manifold outlet of the mix inlet manifold and secure with retaining clip See Figure 2 5 4 If using two mix bags repe...

Page 13: ...to Figure 3 1 for the location of the operating controls on the machine For the information regarding error codes displayedonthecontrolpanel refertothetroubleshooting section of this manual A MAIN FR...

Page 14: ...the Freezing Cylinder OFF ON switch to the OFF position or press the CLEAN button again If the machine is left in CLEAN for more than 20 minutes an error code E4 will be displayed on the display pane...

Page 15: ...nt door 3 Remove the front door by pulling it off the studs 4 Remove the air bleed valve by unscrewing the knob while holding the valve stem from behind Remove the compression spring and push the air...

Page 16: ...Use a soft cloth or sponge to apply the cleaner For best results wipe with the grain of the steel A Clean the rear seal surface from inside of the freezing cylinder B Using sanitizing solution and the...

Page 17: ...and Drug Administration require that all cleaning and sanitizing solutions used with food processing equipment be certified for this use When sanitizing the machine refer to local sanitary regu lation...

Page 18: ...row button once The display will read BASIC 10 Press the up arrow button once The display will read CutOut amps 11 Press the SET button A cursor will start blinking under the far right digit 12 Change...

Page 19: ...pigot to allow the mix to flush out about 8 ounces 0 23 liters of sanitizing solution and liquid mix G Open the air bleed valve on the front door by pressing and holding Hold the valve open until the...

Page 20: ...rough a second check valve on the piston upstroke The air and mix join at the tee and then travel to the machine C The overrun adjustment is preset at the factory If an adjustment becomes necessary re...

Page 21: ...if applicable as an assembly from the mix container C Completely disassemble the hose assembly and the check valve Fig 3 10 Place hoses tee checkvalveassembly andpickuphoseadapterin 90 to 110 F 32 C...

Page 22: ...16...

Page 23: ...the control panel are disabled Follow the instructions below to lock the control panel A Press and hold the PUSH TO FREEZE button for at least 5 seconds B While still holding the PUSH TO FREEZE butto...

Page 24: ...ne temperature on the freezing cylinder and drive motor amps are available on the same screen to assist with setup and troubleshooting Aux Temp F This reading provides the ambient temperature around t...

Page 25: ...of the refrigerant gas in the evaporator at the front of the freezing cylinder Changingthissettingchangesthetemperatureat which the freezing cycle starts This value along with the CutOut value determ...

Page 26: ...g Cab Off will not be shown on the IntelliTec menu Cab On If the Refriger value is set to Cabinet and the temperaturesensorinthecabinetfails thissetting determines the length of the refrigeration cycl...

Page 27: ...e any pressure by opening the spigot C Grasp the pickup hose end of the mix pump hose with one hand and turn the pump on Pull down on the pickup hose end until 12 to 14 inches of tubing has fed throug...

Page 28: ...SEL button press the up arrow button The LCD Screen will read Display B Release both buttons C Press the left arrow button three 3 times to navigate to the Storage menu D Press the up arrow button onc...

Page 29: ...tely B Monthly checks 1 Check drive belts for wear and tighten belts if necessary Refer to section 4 12 2 Check the condenser filter for dirt Refer to section 4 13 4 15 EXTENDED STORAGE Refer to the f...

Page 30: ...24...

Page 31: ...rally caused by very low mix levels in the machine s mix container or from product breakdown Another common cause results from a restriction preventing mix from entering the freezing cylinder Check th...

Page 32: ...the error persists contact your Authorized Stoelting Distributor for further assistance Error Code 9 High Pressure Cutout High Pressure Cutout Errors E9 are usually caused by a dirty or inefficient c...

Page 33: ...rrun setting 2 Raise overrun See Section 4 8 3 Low pump pressure 3 Check pump pressure 4 Large air pocket in barrel 4 Purge air from barrel 5 Auger turning counter clockwise 5 Change rotation to clock...

Page 34: ...F DRAW 2 3 PINTS TO REDUCE SYSTEM PRESSURE TO ZERO TURN PUMP ON PURGE REMAINING AIR IN MIX BAG AND PICK UP HOSE IMPORTANT Before connecting the pick up hose to the mix bag remove as much air from the...

Page 35: ...ing Distributor Dispensed product air pops 1 Overrun setting too high 1 Decrease overrun setting 2 Mix pump hose service life is exceeded 2 Reposition replace mix pump hose 3 Overdrawing the machine s...

Page 36: ...30...

Page 37: ...Parts 2 324509 Decal Cleaning Instructions 1 324566 Decal Wired According To 1 324584 Decal Adequate Ventilation 3 2 324594 Decal Attention Heat Sensitive 1 324686 Decal Danger Automatic Start 1 3247...

Page 38: ...2 624678 O Ring Rear Seal Rear Seal Adapter Black 5 Pack 2 625133 O Ring Front Door Red 1 667868 Seal Rear Auger Orange 1 694200 Spring Air Bleed Valve 1 694255 Spring Auger Flight 5 744273 Tray Drip...

Page 39: ...g 1 4 ID Clear Air Line 25 Increments Per Inch Cab 13 756079 Tubing 3 8 ID Clear Mix Line 25 Increments Per Inch Cab 24 756088 Tubing 1 2 ID Clear Mix Line 25 Increments Per Inch Cab 6 756204 Tubing 1...

Page 40: ...34...

Page 41: ...bligations remedies are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Checklist Warranty Registration Card for the affected equipment b gives Stoelting pr...

Reviews: