STOBER
8 | Commissioning
11/2019 | ID 442710.03
27
3.
Check the default settings and adapt the process data to be transferred to your requirements if necessary.
A90[0] – A90[5], A91[0] – A91[5], A92[0] – A92[5]:
Parameters whose values are received by the drive controller from the controller. The position provides information
about the associated receiving sequence.
4.
Resulting data length
:
Overall length of the data to be transmitted. This may not exceed the value
1
stored in the controller. If necessary,
change the type or number of process data modules to be transmitted in the controller hardware configuration.
8.1.3.2
Adapting TxPZD
Information
Be aware that the maximum overall length of the parameters to be transferred is determined by the selection of
corresponding process data modules in the controller hardware configuration.
ü
You have projected the
Drive Based
application.
1.
Highlight the relevant drive controller in the project tree and click on the first projected axis in the project menu >
Wizard
area.
2.
Select the
PROFINET
wizard >
Transmitted process data TxPZD
.
3.
Check the default settings and adapt the process data to be transferred to your requirements if necessary.
A94[0] – A94[5], A95[0] – A95[5], A96[0] – A96[5]:
Parameters whose values are received by the drive controller from the controller. The position provides information
about the associated receiving sequence.
4.
Resulting data length
:
Overall length of the data to be transmitted. This may not exceed the value
2
stored in the controller. If necessary,
change the type or number of parameter values to be transmitted in the controller hardware configuration.
1
Max. 72 bytes/36 words
2
Max. 72 bytes/36 words