Stober C Series Operating Manual Download Page 4

2SHUDWLQJPDQXDO

*HDUXQLWVDQGJHDUHGPRWRUV

1

2013-06-24

WE KEEP THINGS MOVING

ID 441972.06

en

Please comply with the supplementary operating 
manual ID 4425

91

 for use of the gear units in areas 

where there is risk of explosion !

This operating manual contains information on the transport, 
installation and commissioning of STÖBER Gear Units, 
Geared Motors and their components.
In the event of any unclear points, we recommend that you 
contact STÖBER with the model designation and serial 
number, or have the installation and maintenance work 
carried out by a STÖBER service partner.

1

Operation in accordance with its 
intended use

Gear Units/Geared Motors may be used only for the operation 
of machines and equipment. It is necessary to comply with 
the limits defined by the technical data.
If Gear Units/Geared Motors are to be used for lifting or 
holding loads, the machine design engineer must determine 
whether additional safety measures are necessary.
All operating factors must be taken into account when 
configuring Gear Units/Geared Motors (see configuration aids 
in the STÖBER catalogs). On grounds of operational safety, 
the Gear Units/Geared Motors may then be used only for the 
purpose for which they were configured. Any overload to the 
gear units is deemed non-intended use.
The fulfillment of any warranty claims requires exact 
compliance with the information and instructions in this 
operating manual. Modifications to the Gear Units/Geared 
Motors will void the warranty.
Standard models of Gear Units/Geared Motors may be 
operated only at ambient temperatures between 0 °C and +40 
°C.

NOTICE

Provide for unhindered air circulation in order to prevent 
heat accumulation in the entire drive system (maximum 
permissible gear unit temperature 

 80 °C, with synthetic 

transmission lubricant 

 90 °C).

X

For operation outside of this temperature range, the drive 
unit must be equipped accordingly at the factory (for 
deviating ambient temperatures, see the attached order 
confirmation).

Observe the safety and hazard information in this operating 
manual and all supplementary documents on   Gear Units/
Geared Motors and other components!

2

Technical data

The technical data for the Gear Units/Geared Motors and 
associated components is specified on the respective rating 
plates. This refers to the transmission lubricant used (also 
specified on the rating plate). Further technical data and 
dimensional drawings can be found in the corresponding 
STÖBER catalogs.

NOTICE

For gear units with motor adapter:

X

Please comply with the permissible torques. Limit the 
power at the drive controller, if necessary.

3

Safety information

In addition to the information in this operating manual, you 
must also comply with the applicable national, local and 
facility-specific regulations.

WARNING!

- Danger of electrical shock if unpainted parts conducting 
voltage are touched. Due to the permanent magnets that 
are installed, voltage is applied to the motor connections 
when the fan is rotating!

- Moving and rotating parts can cause injuries

- Touching the gear unit and motor housing may cause 
burns (surface temperatures of over 100°C are possible)

X

The machine manufacturer must provide suitable 
protective measures. The connector or terminal box 
cover of the motor must remain closed during operation. 

All work on the drive must only be performed when no 

current is present.

3.1 Personnel requirements

All work on the electrical equipment of the drive units must be 
performed by qualified electricians. Installation, maintenance 
and repairs of mechanical parts must be performed by fitters, 
industrial mechanics or persons with comparable 
qualifications.

3.2 In the event of disruptions

Summary of Contents for C Series

Page 1: ...l zulässige Getriebetemperatur 80 C bei synthetischem Getriebeschmierstoff 90 C X Für den Betrieb außerhalb dieses Temperaturbereiches muss der Antrieb werkseitig dafür ausgerüstet worden sein abweichende Umgebungstemperatur siehe beigefügte Auftragsbestätigung Beachten Sie die Sicherheits und Gefahrenhinweise in dieser Betriebsanleitung und allen ergänzenden Dokumenten zu Getriebe motoren und zu ...

Page 2: ...Getriebe der Größen C0 C5 F1 F6 FS1 FS6 K1 K4 KL1 KL2 KS4 KS7 und W0 sind allseitig verschlossen und werden nicht entlüftet Die Getriebe der Größen C6 C10 K5 K10 S0 S4 dagegen werden standardmäßig entlüftet sofern nicht anders festgelegt wobei die Position des Entlüftungsventils von der Getriebeeinbaulage abhängig ist Die Metallentlüftungsventile sind mit einer Transportsicherung gegen Schmierstof...

Page 3: ...KS4 KS7 und W0 sind mit einer Langzeitschmierung versehen und bedürfen bei bestimmungsgemäßem Einsatz keiner Wartung Bei den Getrieben der Größen C6 C9 K5 K10 müssen Sie nach 10 000 Betriebsstunden einen Schmierstoffwechsel vornehmen bei Einsatz in Nassräumen nach 5000 Betriebsstunden Schneckengetriebe S0 S4 generell nach 5000 Betriebsstunden Die Getriebe sind mit der auf dem Typschild angegebenen...

Page 4: ...e gear unit temperature 80 C with synthetic transmission lubricant 90 C X For operation outside of this temperature range the drive unit must be equipped accordingly at the factory for deviating ambient temperatures see the attached order confirmation Observe the safety and hazard information in this operating manual and all supplementary documents on Gear Units Geared Motors and other components ...

Page 5: ...not ventilated The gear units of the sizes C6 C10 K5 K10 S0 S4 are as standard ventilated unless otherwise spezified the position of ventilation valve depends on the mounting position of the gear unit The metal ventilation valves are closed with a transport safety device to prevent lubricant leakage Remove the transport safety device before commissioning the drive unit 5 2 Installation of gear uni...

Page 6: ...7 and W0 are equipped with long term lubrication and require no maintenance when used as intended The gear units of the sizes C6 C9 K5 K10 require a lubricant change after 10 000 service hours if used in wet areas after 5000 service hours Helical worm gear unit S0 S4 always needs a lubricant change after 5000 hours The gear units are filled with the quantity and type of lubricant specified on the ...

Reviews: