19
AFTER SALES SUPPORT
1300 886 649
AUS
MODEL: STR-X70GH PRODUCT CODE: 53105 03/2016
Installation (Cont.)
Fig. 11
A
B
Fig. 12
C
D
E
Burner
NG
4”WC / 1.00kPa
ULPG
11”WC / 2.75kPa
NGC
Nozzle Size
NGC
Nozzle Size
Auxiliary
burner
3.6 MJ/h
0.87mm
3.3 MJ/h
0.51mm
Semirapid
burner (x2)
6.3 MJ/h
1.13mm
6.0 MJ/h
0.67mm
Rapid burner
10.8 MJ/h
1.45mm
10.2 MJ/h
0.87mm
Wok burner
13.7 MJ/h
1.65mm
12.7 MJ/h
0.95mm
• Adjust the correctly rated injectors
as illustrated in Fig. 12. Light the
burner and turn the knob to the LOW
position. To remove the knob (C),
simply lift it off the shaft (E). Insert
a small screwdriver (D) into the top
of the shaft (E) and turn the bypass
screw left or right until the flame of
the burner is properly regulated to the
Reduced Rate
position.
Table 1: Injector replacement
NOTE:
To convert the appliance back for use with Natural Gas, perform the
above steps but using the NG injectors.
• Remove the burner heads, caps and
rings from each burner as illustrated
in Fig. 11. Using a socket spanner
(A) undo the injector (B) from each
burner and replace the correctly rated
injector as shown in Table 1 below.