11
AFTER SALES SUPPORT
1300 886 649
AUS
MODEL: STR-X70GH PRODUCT CODE: 53105 03/2016
Important installation advice
• Natural gas / ULPG:
This appliance is intended for use with natural gas. If
it is to be used with LPG, follow the conversions instructions on page 19.
• Location:
The cooktop may be located in a kitchen, kitchen/dining room
or a bed-sitting room, but
not
in a room containing a bath or shower. The
cooktop must
not
be installed in a bed-sitting room of less than 20m
3
.
If used with LPG, the cooktop shall not be installed in a room or space
below ground level, such as in a basement.
• Other use:
This appliance is unsuitable for use in marine craft, caravans
or mobile homes unless each burner is fitted with a flame safeguard.
• Heat resistance of surrounding surfaces:
Wall and bench surfaces
must be capable of sustaining temperatures of 95°C. All laminates,
fixing adhesive and surfacing materials must be certified suitable for
this temperature. We assume no liability for any damage caused if the
appliance is installed contrary to this advice. Do not install the cooktop
near curtains or other flammable materials.
• Ventilation requirements:
This appliance must only be used in rooms
equipped with adequate ventilation. The use of a gas cooking appliance
results in the production of heat and moisture in the room in which
it is installed. Always ensure that the kitchen is well ventilated; keep
natural ventilation holes open or install a mechanical ventilation device
(mechanical extractor hood).
Prolonged intensive use of the appliance may require additional or more
effective ventilation, for example, opening of a window or increasing the
level of mechanical ventilation, where present.
Important clearances: please note!
• Fire resistant materials
(such as ceramic tiles) are required up to 450mm
above the burner top.
• Walls or vertical structures
must be at least 200mm away from the burner.
• There must be a minimum clearance of 50mm between the base of the
appliance and a
combustible surface
.
• There must be no
overhanging surfaces
, and no rangehood or exhaust
system, within 750mm above the burner tops.
• If fitting a 600mm
bridging unit
above the 700mm cooktop unit, the sides
of adjacent cabinets may be lower than 650mm down to 400mm, provided
that they are resistant to heat and steam.
Installation (Cont.)