Cleaning Systems Safety Manual

Hazardous substances (such as 
asbestos or oil) must not be allowed to 
escape into the environment unchecked 
when working with the machine. 
The applicable environmental 
regulations must be observed without 
fail!

Surfaces of asbestos cement must 
never be cleaned with a high-pressure 
jet, as hazardous, breathable asbestos 
fibres may be released in addition to the 
dirt. The danger is greatest when the 
washed surface has dried.

The machine must 
immediately be 
unplugged from the 
mains supply if the power 
cable is damaged - 

danger due to electric 
shock.

Delicate parts made of rubber, fabric or 
similar materials must not be cleaned 
with a pencil jet, e.g. from the rotary 
nozzle. Maintain a sufficient distance 
between the high-pressure nozzle and 
the surface in order to avoid damaging 
the surface to be cleaned.

The trigger on the spray gun must move 
easily and automatically return to its 
starting position when released.

Always check that the machine is in 
good working order before starting work. 
Pay particular attention to the power 
cable, mains plug, high-pressure hose, 
spray attachment and safety 
mechanisms.

The machine may only be operated in an 
upright position.
Do not cover the machine and ensure 
adequate motor ventilation.

Keep the high-pressure cleaner as far 
away as possible from the object being 
cleaned.

Ensure that the power cable is not 
damaged by being driven over, 
squashed or pulled, etc.

Never disconnect the machine by pulling 
the cable out of the socket: always grip 
the plug itself.

The power cable and mains plug must 
never be touched with wet hands!

Always unroll the power cable from the 
cable drum completely to avoid all risk of 
fire due to overheating.

Hold the spray attachment firmly with 
both hands in order safely to withstand 
the kickback force and additional torque 
produced when using spray attachments 
with angled spray lance.

Always ensure a firm and safe footing. 

The voltage and frequency specified for 
the machine (see rating plate) must 
match those of the mains power supply.

Safety device

When the safety device is tripped, any 
impermissibly high pressure will be 
diverted back to the intake side of the 
high-pressure pump via an overflow 
valve.
This safety device is set by the 
manufacturer and must not be adjusted.

Summary of Contents for Plus se 121

Page 1: ...Cleaning Systems Safety Manual STIH SM_HR_01_U_K6 book Seite 0 Donnerstag 19 Oktober 2006 8 14 08...

Page 2: ...al instruction manuals for STIHL cleaning systems With the aid of this booklet even long standing users of a cleaning system can familiarize themselves in their own best interests with the latest find...

Page 3: ...ied in any way this may also lead to accidents or damage to the machine High pressure hoses fittings and couplings are very important for the safety of the machine Only high pressure hoses fittings co...

Page 4: ...ent Wear shoes with non slip soles Wear goggles and protective clothing STIHL recommends that a boilersuit be worn in order to reduce the risk of injury due to accidental exposure to the high pressure...

Page 5: ...ular attention to the power cable mains plug high pressure hose spray attachment and safety mechanisms The machine may only be operated in an upright position Do not cover the machine and ensure adequ...

Page 6: ...e all safety instructions specific to your country such as those issued by the employers liability insurance association social insurance institutions public authorities responsible for occupational s...

Page 7: ...ess pressure of the machine The permissible excess pressure the maximum permitted temperature and the date of manufacture are stated on the cladding of the high pressure hose The permissible pressure...

Page 8: ...aces containing asbestos cement as dangerous breathable asbestos fibres may be released in addition to the dirt The danger is greatest when the correspondingly cleaned surface has dried Do not smoke n...

Page 9: ...he exhaust outlet and keep away from the exhaust outlet Do not cover the exhaust outlet Risk of burns and fire The voltage and frequency specified for the machine see rating plate must match those of...

Page 10: ...plug never the cable to unplug Inspect the power cable regularly for signs of damage or ageing Never use the machine if the power cable is damaged in any way risk of electrocution The main plug must b...

Page 11: ...nk handle for hose reel 13 Bracket for spray attachment 14 Bracket for power cable 15 Bracket for high pressure hose 16 Bracket for nozzles 17 Bracket for cleaning pin 18 Bracket for spray set 19 Brac...

Page 12: ...Fuel tank 12 Machine cover 13 Pressure gauge 14 Handle on machine cover 15 Indicator for operating condition 16 Pump oil indicator 1 17 Service indicator 18 Scale inhibitor indicator 1 19 Fuel indicat...

Page 13: ...handle for hose reel 32 High pressure hose connection machines without hose reel 33 Metering valve for scale inhibitor 34 High pressure pump 35 Safety valve block 36 Expansion tank for oil 37 Rotary...

Page 14: ...Catches 7 Intake port for connecting the suction hose 8 Castor with parking brake 9 Container 10 Holder for nozzles and accessories 11 Filter cleaning button 12 Handle 13 Suction tube 14 Floor tool 1...

Page 15: ...0457 190 0121 englisch English SM_HR_01_U_K6 book Seite 1 Donnerstag 19 Oktober 2006 8 14 08...