64
MS 271 C, MS 291 C
Installing unwound rewind spring
If the rewind spring has popped out,
refit it in the fan housing as follows:
– Arrange the rewind spring (1) in
its original position.
:
Fit the anchor loop in its
seat (arrow) in the fan housing.
:
Fit the rewind spring (1)
clockwise in the housing, holding
the windings steady in the
process.
The procedure is otherwise the
same as that for installing a new
rewind spring.
5902RA221 TG
1
5902RA222 TG
1
Models with ErgoStart
As the spring seat is deeper on this
model, the rewind spring cannot be
fitted directly in the fan housing.
:
Fit the anchor loop in its seat
(arrow) in the frame.
:
Fit the rewind spring (1)
counterclockwise in the frame,
holding the windings steady in
the process.
:
Check the washer (1) and
replace it if necessary.
The procedure is otherwise the
same as that for installing a new
rewind spring.
– Secure the spring so that it
cannot pop out.
– Install the rope rotor,
– Reassemble all other parts in the
reverse sequence.
5902RA608 TG
1
5902RA223 TG
1