Fit new spring housing - bottom
plate must face downward.
Engage outer spring loop over the
lug.
•
Refit the rope rotor.
Go to "Tensioning rewind spring".
•
If the spring has popped out and
uncoiled:
Refit it in the counterclockwise
direction - start outside and work
inward.
7HQVLRQLQJUHZLQGVSULQJ
•
Make a loop in the unwound starter
rope and use it to turn the rope
rotor six full revolutions in the
direction of the arrow
•
Hold the rotor steady -
straighten the twisted rope -
•
Release the rotor -
•
Let go of rope slowly so that it winds
onto the rotor.
The starter grip must sit firmly in the
rope guide bush. If the grip droops
to one side: Increase spring tension
by one additional turn.
•
When starter rope is fully extended
it must be possible to rotate the rotor
at least another half turn. If this is
not the possible, the spring is over-
tensioned and could break
Take off one turn of the rope.
•
Fit the fan housing on the
crankcase.
•
Tighten down the screws firmly.
•
Set the Master Control lever to
353BA029
353BA030
%5