background image

Part #111325-001

Product Manual:

Model #1453

Centrifugal Blower

T.A. Pelsue Company

2500 South Tejon Street

Englewood, Colorado, USA  80110

Tel. 800-525-8460 or 303-936-7432 

Fax. 303-934-5581

Internet: www.pelsue.com  

Email: [email protected]

ISO 9001 Certified

Summary of Contents for 1453

Page 1: ... Manual Model 1453 Centrifugal Blower T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Page 2: ... 111325 001 Product Manual Model 1453 CENTRIFUGAL BLOWER Revision 04 Date 06 05 2015 Page 2 ...

Page 3: ...ntinuing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance nation...

Page 4: ...eneral Information 5 1 1 Quality Policy 1 2 Pelsue Product Warranty 2 0 Introduction Product Information 7 2 1 Serial Number 3 0 Configuration Assembly 8 3 1 Parts Diagram List 4 0 Safety 10 4 1 Safety Alert Symbol 4 2 General Safety Information 5 0 Product Operation 12 5 1 Product Description Capabilities 5 2 Start Up Operating Procedures ...

Page 5: ...atisfaction is one of the differentiators that sets you apart from the pack and yields a competitive advantage Therefore we will support total customer satisfaction by implementing the ISO 9001 Quality System and providing the necessary atmosphere and training to nurture this concept throughout our organization We will make every business decisionas though the quality of the part or service provid...

Page 6: ...eunder shall be limited to the repair or replacement of the product or component as set forth above and shall not include any liability whatsoever for damages caused by such failure including but not limited to consequential or incidental damages flowing from use or lack of use of product Any replacement repair modification installation or other service performed by the T A Pelsue Company shall be...

Page 7: ...s manual available for future reference if required and as a tool in the training of new operators This product is a part of a system for confined space ventilation operations The user must read understand and follow the instructions contained in this manual before using this equipment Failure to follow these instructions could result in serious injury or death 2 1 Serial Number Product Serial Num...

Page 8: ...damage If damage to any of the components is discovered Alert the shipping carrier immediately of the damage to the shipment Refer to the following parts breakdown diagram Figure 3 1a and the accompanying parts list Table 3 1a for iden tification of parts in the event replacements become necessary The parts list table displays applicable part numbers descriptions and quantity per assembly Replacem...

Page 9: ...HER FLAT 5 16 TYPE A W PLATED 16 18 112394 001 ENGINE HONDA 4HP GASOLINE ROPE START 1 19 124347 700 INSERT FOR 7 00 BLOWER WHEEL FORMED ALUMINUM 1 20 100157 007 SCREW HEX HD 5 16 18 UNC X 3 LONG PLATED 4 21 107942 001 NUT STOVER 5 16 18 UNC GRADE 5 12 22 100157 015 SCREW CAP HEX HD 5 16 18 UNC X 2 1 2 PLATED 4 23 101427 002 SCREW CAP HEX HD 1 20 UNC X 3 PLATED 4 24 100050 009 WASHER FLAT 1 IN TYPE...

Page 10: ...he 1453 Centrifugal Blower and alert you to good safety and operating practices while using the system Remember you are the key to safety Good safety practices not only protect you but also the people around you Make these practices a working part of your safety program Be certain that everyone operating in or around a confined space is familiar with the procedures recommended and follows safety p...

Page 11: ...items 1 Do not use the blower for anything other than its intended use 2 Do not wear loose clothing that can become entangled in operating machinery Do not operate the blower without inlet or outlet grilles in place 3 Do not place fingers or any other object through inlet or outlet grilles 4 To prevent exhaust fumes from being pulled into the blower intake never run the engine in an enclosed area ...

Page 12: ...bs Height 19 7 8 Width 18 Length 18 3 8 5 1 Product Description Capabilities The following section will address the capabilities and the general operation of the Pelsue Model 1453 Centrifugal Blower The instructions contained within this section should be adhered to each and every time the product is used Any person tasked with installing or operating this piece of equipment should be familiar wit...

Page 13: ...ment is in good operating condition prior to usage Equipment that is not in good condition can endanger the safety of the entrant s and attendant s during use The Pre Operation Visual Inspection is not limited to but must include the following items a Check that the blower inlet and outlet grilles for obstructions b Ensure that the exhaust and the air intake of the engine are not obstructed c Chec...

Page 14: ... felt Then rapidly pull the cord to overcome engine com pression and prevent kickback e After the engine has started gradually move the choke lever to the OPEN position The engine speed can now be adjusted to the desired speed by moving the throttle lever f To shut down the blower turn the ignition switch and the fuel lever to the OFF positions Do not move the choke lever to the CHOKE position to ...

Page 15: ...Notes ...

Page 16: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Reviews: