STIEBEL ELTRON WTS 30 E Operating And Installation Download Page 6

18

 |WTS 

WWW.STIeBel-elTROn.cOM

Installation  

 

Installation

f

f

Remove the wall mounting bracket from the lower shell, and 

secure it to the wall with the 8x70 screws and washers.

D

00000

33

56

8

f

f

Hook the lower shell and the appliance into the wall 

mounting bracket, and secure the appliance to the wall with 

the 8x100 screws and washers.

D

00000

33

584

9.2  water connection

!

 

CAUTION Risk of damage through water

Carry out all water connection and installation work in 

accordance with regulations.

Connect the pipework according to the following diagram.

1

3

5

4

2

D

00000

33

58

6

1  Heat pump return

2  Heat pump flow

3  DHW cylinder flow

4  DHW cylinder return

5  DHW cylinder

f

f

Install a blow-off line, and route this out of the appliance 

through the entry provided in the lower shell.

f

f

Size the drain so that water can drain off unimpeded when 

the safety valve is fully opened. The blow-off aperture of the 

safety valve must remain open towards the atmosphere.

f

f

Fit the blow-off line of the safety valve with a constant slope.

Summary of Contents for WTS 30 E

Page 1: ...n et Installation Gebruik en Installatie Obsluha a instalace Ladestation f r Warmwasserspeicher Charging station for DHW cylinders Station de charge pour ballon d eau chaude sanitaire Laadstation voor...

Page 2: ...ING Risk to life through electrocution CAUTION Risk of injury through burns f f The symbol indicates that you should do something The action you need to take is described step by step Passages with th...

Page 3: ...aged 8 and up and persons with reduced physical sensory or mental capabilities or a lack of experience provided that they are supervised or they have been instructed on how to use the appliance safel...

Page 4: ...instructions NOTE In accordance with current technical rules install a DHW filter in the potable water line 7 Device description This appliance comprises several components that are described in the...

Page 5: ...Risk of damage through corrosion Copper solder is used inside the heat exchanger Therefore ensure that no steel pipes are used in the flow direction downstream of the heat exchanger Dissolved copper...

Page 6: ...out all water connection and installation work in accordance with regulations Connect the pipework according to the following diagram 1 3 5 4 2 D0000033586 1 Heat pump return 2 Heat pump flow 3 DHW c...

Page 7: ...f For this observe the heat pump operating and installation instructions f f Carefully vent the appliance 10 2 Filling the DHW cylinder circuit CAUTION Risk of injury through scalding Water lines and...

Page 8: ...capacity primary side l 1 4 3 0 Heat exchanger capacity secondary side l 1 5 3 1 Residual head primary side hPa 478 476 Residual head secondary side hPa 240 263 Max permissible pressure primary side M...

Page 9: ...sh Installation Specification Dimensions WTS 30 E 500 860 265 10 596 115 265 130 221 421 221 321 80 e23 e22 d02 d01 b01 D0000017263 WTS 30 E d01 Heat pump flow G 1 d02 Heat pump return G 1 e22 Cylinde...

Page 10: ...llation Specification Dimensions WTS 40 E 520 860 1089 1274 267 8 115 265 130 340 440 80 340 440 599 e23 e22 d02 d01 b01 D0000017264 WTS 40 E d01 Heat pump flow G 1 d02 Heat pump return G 1 e22 Cylind...

Page 11: ...uch warranties are only granted if the subsidiary has issued its own terms of warranty No other warranty will be granted We shall not provide any warranty for appliances acquired in countries where we...

Page 12: ...720 9989 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26 info stiebel eltron fr www stiebel...

Reviews: