Safety
6. safety
Only qualified contractors should carry out installation,
commissioning, maintenance and repair of the appliance.
CAUTION Risk of injury through burns!
Contact with hot components can lead to burns.
Therefore:
-
When working on hot components, always wear
protective working clothing and gloves.
-
Before commencing work on the appliance, ensure
that all its components have sufficiently cooled
down.
6.1 general safety instructions
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
6.2 instructions, standards and regulations
NOTE
Observe all applicable national and regional regulations
and instructions.
NOTE
In accordance with current technical rules, install a DHW
filter in the potable water line.
7. device description
This appliance comprises several components that are described
in the following diagrams.
7.1 wts 30
7.1.1 Heat pump circuit
1
3
4
3
1
2
5
D
00000
33
58
5
1 Ball valve
2 Circulation pump
3 Flushing, drain and fill connection
4 Plate heat exchanger
5 Non-return valve
InSTallaTIOn
7.1.2 dHw cylinder circuit
5
1
1
3
4
26
�0
3�
14
�0
02
2
2
6
1 Ball valve
2 Circulation pump
3 Flushing, drain and fill connection
4 Plate heat exchanger
5 Safety valve
6 Non-return valve
7.2 standard delivery wts 30
Delivered with the appliance are:
- Wall mounting bracket
- Screws 8x70
- Screws 8x100
- Washers
- Rawl plugs
- Upper shell, thermal insulation
- Lower shell, thermal insulation
7.3 wts 40
7.3.1 Heat pump circuit
1
1
2
3
4
3
5
D
00000
33
58
7
1 Ball valve
2 Circulation pump
3 Flushing, drain and fill connection
4 Plate heat exchanger
5 Non-return valve