9

 

the radiator does not 
get warm?

 

if liquid comes out of the 
heater?

 

when the sevice techni-
cian has been called?

Check whether . . .
. . .  the ON/OFF button (

1

) is switched on.

. . .  the appropriate fuse in your fuse box has been connected or the residual current circuit breaker has 

been switched off.

Remove the cause! 

If the heater still does not warm up, call a qualified installer.

Switch the radiator off and then on:

– the LED indicator “appliance heating up” flashes 3 times, the measuring probe is damaged. 

Call a qualified installer.

– the LED indicator “appliance heating up” flashes 5 times, the mains voltage to the appliance is too high. 

Switch the heating element off. 

Call a qualified installer.

Switch off the unit and pull out the supply plug! 

Call a qualified installer or service technican!

Inform the service technician about the 

type

 of unit (Typ) and it‘s 

number

 (Nr.) 

that is found on the rating plate (

20

)!

What to do if …?

The installation (electrical work) and commis-
sioning as well as maintenance of this appli-
ance must be carried out only by an approved 
qualified installer in accordance with these 
instructions.

Only remove the packaging of the unit and 
accessories at the place of installation, taking 
note of the additional package. 
When unpacking, take care to ensure that no 
accessories remain behind in the packaging 
material.

2.1 Equipment description

Wall distance pipe

Screw 5 x 40

10 

Adjusting screw M4 x 10

11 

Spacer

12 

Clamp

13 

Screw M5 x 30

14 

Cap

15 

Raw plug 

8 mm

16 

Mount-hook

17 

Cap

18 

Power supply cable with plug, 
1000 mm long

19 

Fixing bolt

20 

Rating plate

The towel rail radiator is for wall mounting only.
The appliance is ready for installation. The 
heat-transfer-liquid, a water-glycol-mixture, will 
be heated up by the heating element. 
The electrical connection is by means of mains 
plug.
With a protection level of IP 24 (splash proof), 
the radiator can be installed where space is 
restricted (take note of the information on 
the protection range in 2.2 below).

2.2 Instructions and regulations

The appliance must not:

–  Be operated in areas which are subject 

to the risk of fire or explosion due to 
chemicals, dust, gases or vapours;

–  Be operated in the immediate vicinity of 

pipes or containers which carry or con-
tain combustible or potentially explosive 
substances;

–  Be operated, at less as the minimum 

clearance distances advised.

In workshops or other areas in which the 
odour of waste gases, oil, petrol, etc. might 
occur, or in which work is carried out in-
volving solvents and chemicals, there is a 
risk of sustained odour burdens being en-
gendered, and possibly of dirt contamination 
occurring.

  The appliance should only be installed on a 

vertical wall resistant to temperatures above 
90 °C

  The installation wall must have sufficient 

load-bearing capacity (appliance weight, see 
“Specifications”).

  Observe the minimum distances from ad-

joining surfaces of objects.

  The appliance should not be installed im-

mediately below a wall socket.

  All electrical connection and installation 

work must be carried out in accordance 
with the VDE regulations (0100), the regula-
tions of the competent water and electricity 
supply companies as well as the appropriate 
national and regional regulations.

  Follow the rating plate.  The stated voltage 

must be in accordance with the mains voltage.

  If the heating unit is installed in rooms with 

a bath and/or a shower, the range of pro-
tection according to the I.E.E. Regulations- in 

conformity with the information on the unit 
rating plate - must be taken into account.

  The unit is to be fitted in such a way that 

switching and control devices cannot be 
touched by anyone in the bath or under the 
shower. 

  If it needs replacing, the power supply ca-

ble must only be replaced with an original 
Stiebel Eltron spare by a qualified installer.

2.3 Installation

BHE 75

_

 Take the dimensions for drill holes from the 
illustration of the BHE, depending on the 
customer’s existing water connections, and 
mark out on a wall with sufficient load-bear-
ing capacity.  

Observe minimum distances!

_

 Install wall distance pipe (

12

) with enclosed  

raw plugs Ø8 mm (

19

) and screws 5 x 40 

(

13

) depending on the construction of the 

wall.

_

 Push the spacers (

11

) into the wall distance 

pipe and screw into position with the ad-
justing screw M4 x 10 (

10

) (do not tighten).

_

 Position the radiator with the two upper 
cross-pipes on the upper spacers and secure 
in position on the spacers by means of the 
clamp (

12

) (M5 x 30 screw, 

13

). Then fix at 

the bottom in the same way as at the top.

_

 Line up the radiator (push spacers into wall 
bushes), tighten the adjusting screws in the 
wall bushes at the top and put caps (

14

) on 

the clamps.

_

 Plug in the mains plug (

18

).

BHE 75 L

_

 Determine the dimensions of drill-holes 
according to the fixing bolts (

19

) or deter-

mine it from the dimensional drawing of the 
BHC-L and mark it on a sufficient load-car-

2. Installation instructions

 

 for qualified installer

Typ:  BH. . . . .   

Nr.: . . . . . .  -  . . . .  -  . . . . . .

Summary of Contents for Thermocon BHE 75

Page 1: ...h Bad Handtuch Heizk rper Gebrauchs und Montageanweisung English Towel rail radiator Operating and installation instructions Fran ais Radiateur s che serviettes Notice d utilisation et de montage Nede...

Page 2: ...Initial start up 2 5 Hand over 3 Environment and recycling 10 4 Guarantee 10 Contenu Fran ais page 11 13 1 Notice d utilisation 11 1 1 Description de l appareil 1 2 Commande L essentiel en bref 1 3 Co...

Page 3: ...220591 0 75 kW 1 N 230 240 V 50 H 3 2 A 60 59 1114 428 448 150 78 550 140 1436 1 4 h 1 2 h 1 h 2 h 1 4 h 1 2 h 1 h 2 h 1 4 h 1 2 h 1 h 2 h 1 4 h 1 2 h 1 h 2 h 1 4 h 1 2 h 1 h 2 h 1 4 h 1 2 h 1 h 2 h 1...

Page 4: ...absinken Frost schutz so ist der Raumtemperatur Regler auf Stellung zu drehen und das Ger t muss eingeschaltet bleiben Heizleistung des Ger tes und W rmebedarf des Raumes beachten Au erbetriebnahme Z...

Page 5: ...uftreten oder mit L sungsmitteln und Che mikalien gearbeitet wird kann es zu l nger anhaltenden Geruchsbel sti gungen und ge gebenenfalls zuVerunreinigungen kommen Das Ger t darf nur an einer senkrech...

Page 6: ...er Produktverantwortung f r eine umweltgerechte Behandlung und Verwertung der Altger te Weitere Informationen erhalten Sie ber Ihre Kommune oder Ihren Fachhandwerker Fachh ndler ber das R cknahmesyste...

Page 7: ...assen oder selbst auszuf hren Etwaige ausgewechselte Teile werden unser Eigentum F r die Dauer und Reichweite der Garantie bernehmen wir s mt liche Material und Montagekosten Soweit der Kunde wegen de...

Page 8: ...heating capacity of the appliance and heat requirement of the room Taking the appliance out of operation In order to take the equipment completely out of operation switch it off take the supply plug o...

Page 9: ...workshops or other areas in which the odour of waste gases oil petrol etc might occur or in which work is carried out in volving solvents and chemicals there is a risk of sustained odour burdens bein...

Page 10: ...stances _install the mount hook 16 depending to the wall construction with suitable mount ing materials e g with enclosed raw plugs 8 mm 15 of and screws 5 x 40 9 _Hang the radiator on the retaining h...

Page 11: ...de la valeur r gl e sur le r gulateur de temp rature am biante La dur e de chauffage peut tre r gl e avec le minuteur pour dur e r duite 6 sur h h 1 h ou 2 h et activ e en appuyant sur la touche de ch...

Page 12: ...ves si les distances minimales par rapport aux objects ne sont pas respect es Dans les ateliers ou dans d autres locaux dans lesquels il se d gage des manations de gaz d chappement d odeurs d huile et...

Page 13: ...d cartement dans les manchons muraux serrez les vis d ajustage au dessus dans les manchons muraux et placer les caches de protection 14 sur les triers de serrage _Mettre la fiche 18 dans la prise de...

Page 14: ...die op de ruimtetemperatuurrege laar is ingesteld La dur e de chauffage peut tre r gl e avec le minuteur pour dur e r duite 6 sur h h 1 h ou 2 h et activ e en appuyant sur la touche de chauffage rapi...

Page 15: ...schrijving van het toestel 8 Wandhuls 9 Schroef 5 x 40 10 Instelschroef M4 x 10 11 Afstandsstuk 12 Klembeugel 13 Schroef M5 x 30 14 Afdekkapje 15 Plug 8 mm 16 Ophanghaak 17 Afdekkapje 18 Netaansluitka...

Page 16: ...monteren _Afstandsstuk 11 telkens in de wandhuls schuiven in met instelschroef M4 x 10 10 schroeven niet vastschroeven _Verwarmingselement met de beide boven ste dwarsbuizen op de bovenste afstands st...

Page 17: ...17 Notizen Note Notitie...

Page 18: ...tron com pl Russia STIEBEL ELTRON RUSSIA Urzhumskaya street 4 129343 Moscow Tel 495 775 3889 Fax 495 775 3887 Email info stiebel eltron ru www stiebel eltron ru Sweden STIEBEL ELTRON AB Friggagatan 5...

Reviews: