A1
Control panel PCB
A3
panel
E1
Immersion heater
N1
Protective thermostat
R1
Room temperature sensor
10
3. Environment and
recycling
Recycling of obselete appliances
Appliances with this label must not be
disposed off with the general waste.
They must be collected separately and
disposed off according to local regulations.
For guarantees please refer to the pespective
terms and conditions of supply for your country.
The installation, electrical connection
and first operation of this appliance
should be carried out by a qualified installer.
The company does not accept liability for
failure of any goods supplied which accor-
dance with the manufacturer‘s instructions.
Guarantee
rying wall, depending to the existing water-
connection-points.
Beware the minimum
distances!
_
install the mount-hook (
16
) depending to
the wall construction with suitable mount-
ing materials, e.g. with enclosed raw plugs
Ø8 mm (
15
) of and screws 5 x 40 (
9
).
_
Hang the radiator on the retaining hooks
with the fixing bolts (
19
).
_
Push caps (
17
) with “marking ridge upward”
onto the fixing wall (appliance is fixed).
_
Plug in the mains plug (
18
).
Electrical connection
The appliance must be connected to
AC 230 V ~ 50/60 Hz only.
A socket must be installed at a distance of at
least 10 cm to the side of the heater for the
purpose of the connection.
2.4 Initial start-up
When it is started up for the first time, you
may notice a smell which is caused by any
manufacture-related residues on the radiator.
2.5 Hand-over
Explain the functions of the appliance to the
user. In particular, draw his or her attention to
the safety instructions. Hand over the operat-
ing and installation instructions.
26_07_80_0049
L
N
N1
R1
A1
A3
ϑ>
E
1
L N
N1
R1
A1
(M)
(V)
(B)
��
E
1
26_07_80_0049
BHE 75 L
BHE 75