26
CUSTOMER SERVICE
Cleaning Electrode
The ignition electrode (1) and flame recognition electro-
de (2) have to be cleaned very carefully, after a period of
time they get fragile because of the work they have to
perform.
- Unscrew the screws (3 & 4) and extract the electrode
group (1 & 2) using a little brush with metallic hair for
cleaning, after insert the electrode group (1 & 2) if neces-
sary exchange the seal gasket (5) be real careful to not
damage the electrode.
Pressure switch tubes
Check if there are deposits or condensation within the
pipes pressure measurement:
- Fan combustion air pressure switch.
- Exhaust fumes / pressure.
Blow, disconnect the switch and test it, otherwise, may
be damaged.
Preliminary operations:
-Place the wall switch to the “off” position.
-Close the gas tap.
-Wait that the appliance gets cold completely.
Replacing the Control board with Flame Control
To remove and refit the Flame Control board (1), follow
the instructions below:
- remove the board cover;
- loosen the retention screw (2) of the board cover;
- remove the connectors from their plugs;
- completely replace the electronic board, taking care to
reconnect all the wires properly.
Always check the correct position of switches on
control board.
COMPONENTS REPLACEMENT
2
4
1
3
5
1
2