18
INSTALLER
MOUNTING THE “FLOOR STANDING” SUPPORT
STRUCTURE
The support structure kit is used when the wall selected
for installation is unable to support the weight of the
appliance. Thanks to this accessory, all the weight of the
appliance is discharged onto the floor.
Installation
- check the contents of the KIT;
- choose the installation wall and its actual consistency
for making the hole (A) for the suction and exhaust
pipes;
- assemble the side brackets (1) with the template (2) so
as to create a single structure (5);
- move the single structure up against the wall and with
the help of a spirit level, make the centre of hole (A);
- make the hole (A);
Ø 65 mm hole for Ø 32 mm pipes or Ø 110 mm hole for
Ø 54 mm pipes.
- remove the plate (3) from the template (2);
- fit the unit (4) on the template (2);
- fit and fasten the pipes (10) on the unit (4);
NOTE: Minimum clearance of 85mm from the floor must
be adhered to.
Option A:
- fit the supports (6) on the side brackets (1), using the
adjustment screws (7);
Option B:
- fit the optional base (8) on the side brackets (1);
- fit the new unit (str pipes) on the frame (11) of
the appliance;
- move the appliance up against the wall and level;
- connect the power and gas supplies;
- fit the cover (9);
FLOOR STANDING
1
optional
6
7
9
1
8
9
2
4
1
10
10
2
1
4
11
1
2
3
5
A Ø32
A
= 65
mm
Ø54
A
= 110
mm