23
Legend:
Symbol
Specification
x
Channel is available
x*
Channel is available if the corresponding option is activated.
Adjustment Channels
Channel
Description
Factory setting
Page
Arr
x
System
7
39
DT O
x
Switch-on temperature difference
12.0 °Ra [6.0 K]
39
DT F
x
Switch-off temperature difference
8.0 °Ra [4.0 K]
39
DT S
x
Nominal temperature difference
20.0 °Ra [10.0 K]
39
RIS
x
Rise control R1 / R2
4 °Ra [2 K]
39
n1MN
x
Minimum pump speed R1
30 %
39
S MX
x
Maximum tank temperature
140 °F [60 °C]
40
n2MN
x
Minimum pump speed R2
30 %
39
EM1
x
Emergency temperature collector
270 °F [130 °C]
40
EM2
x
Emergency temperature collector
270 °F [130 °C]
40
OCC1
x
Option collector cooling collector 1
OFF
41
CMX1
x*
Maximum temperature collector 1
230 °F [110 °C]
41
OCC2
x
Option collector cooling collector 2
OFF
41
CMX2
x*
Maximum temperature collector 2
230 °F [110 °C]
41
OSYC
x
Option system cooling
OFF
41
DTCO
x*
Cooling switch-on temperature difference
40.0 °Ra [20.0 K]
41
DTCF
x*
Cooling switch-off temperature difference
30.0 °Ra [15.0 K]
41
OSTC
x
Option tank cooling
OFF
42
OHOL
x*
Option holiday cooling
OFF
42
THOL
x*
Holiday cooling temperature
110 °F [40 °C]
42
OCN1
x
Option minimum limitation collector 1
OFF
42
CMN1
x*
Minimum temperature collector 1
50 °F [10 °C]
42
OCN2
x
Option minimum limitation collector 2
OFF
42
CMN2
x*
Minium temperature collector 2
50 °F [10 °C]
42
OCF1
x
Option antifreeze collector 1
OFF
42
CFR1
x*
Antifreeze temperature collector 1
40.0 °F [4.0 °C]
42
OCF2
x
Option antifreeze collector 2
OFF
42
CFR2
x*
Antifreeze temperature collector 2
40.0 °F [4.0 °C]
42
O TC
x
Option tube collector
OFF
44
TCST
x*
OTC starting time
07:00
44
TCEN
x*
OTC ending time
19:00
44
TCRU
x*
OTC runtime
30 s
44
TCIN
x*
OTC standstill interval
30 min
44
MAN1
x
Manual operation R1
Auto
46
MAN2
x
Manual operation R2
Auto
46
LANG
x
Language
En
46
UNIT
x
Temperature unit
°C
46
RESE
x
Reset - back to factory defaults
46
W0050100
Version number
Summary of Contents for SOM 7 PLUS