background image

oPErATIoN 

 

safety

24

 | DEL  Plus 

www.stiebel-eltron.com

1.2  Other symbols in this documentation

 

Note

General information is identified by the adjacent symbol.

f

f

Read these texts carefully.

symbol

Meaning

 

 

Material losses

(appliance damage, consequential losses and environmen-

tal pollution)

 

 

Appliance disposal 

 

f

f

This symbol indicates that you have to do something. The ac-

tion you need to take is described step by step.

1.3  Units of measurement

 

Note

All measurements are given in mm unless stated oth-

erwise.

2.  Safety

2.1  Intended use

This appliance is suitable for heating domestic hot water or for 

reheating preheated water. The appliance can supply one or more 

draw-off points.
Water will not be reheated if the maximum inlet temperature for 

reheating is exceeded.
The appliance is intended for domestic use. It can be used safely 

by untrained persons. The appliance can also be used in non-do-

mestic environments, e.g. in small businesses, as long as it is 

used in the same way.
Any other use beyond that described shall be deemed inappro-

priate. Observation of these instructions and of the instructions 

for any accessories used is also part of the correct use of this 

appliance.

2.2  General safety instructions

 

CAUTION Burns

During operation, the tap can reach temperatures up 

to 70 °C.

There is a risk of scalding at outlet temperatures in ex-

cess of 43 °C.

 

CAUTION Burns

If operating with preheated water, e.g. from a solar ther-

mal system, the DHW temperature may vary from the 

selected set temperature.

 

!

 

WARNING Injury

The appliance may be used by children aged 3 and older 

and persons with reduced physical, sensory or mental 

capabilities or a lack of experience and know-how, pro-

vided that they are supervised or they have been in-

structed on how to use the appliance safely and have 

understood the potential risks. Children must never play 

with the appliance. Children must never clean the ap-

pliance or perform user maintenance unless they are 

supervised.

Where children or persons with limited physical, sensory or men-

tal abilities are allowed to use this appliance, we recommend a 

permanent temperature limit. The following limitation options 

are available:

 

- User adjustable: Temperature limit (e.g. for childproofing)

 

- Qualified contractor adjustable: Internal anti-scalding 

protection

!

 

Material losses

The user should protect the appliance and its tap against 

frost.

3.  Appliance description

The appliance switches on automatically as soon as you open the 

hot water valve on the tap. When you close the tap, the appliance 

switches off again automatically.
The appliance heats water as it flows through it. The DHW outlet 

temperature can be variably adjusted. From a certain flow rate, 

the control unit regulates the correct heating output, subject to 

the temperature selected and the current cold water temperature.
The electronically controlled instantaneous water heater with au-

tomatic output matching maintains a consistent outlet tempera-

ture. It is irrespective of the inlet temperature, up to the maximum 

output of the appliance.
If the appliance is operated with preheated water and the inlet 

temperature exceeds the selected set temperature, the word "hot" 

and the inlet temperature are displayed alternately, and the "hot" 

LED flashes. The water is not heated further.
You can save and quickly call up different temperatures. With 

the ECO function, the flow rate is limited to 3 preset levels. The 

appliance is equipped with functions to permanently limit the 

temperature (e.g. for childproofing). The backlight switches on 

automatically as soon as water starts to flow through the appli-

ance or you make a change on the user interface. The backlight 

switches off automatically 5 seconds after water stops flowing or 

if no operation has been performed for 30 seconds.
You can set the temperature unit and operating lock individually.

Heating system

The bare wire heating system is enclosed within a pressure-tested 

plastic jacket. The heating system with its stainless steel internal 

indirect coil is suitable for hard and soft water areas and is largely 

insusceptible to scale build-up. The heating system ensures rapid 

and efficient DHW provision.

!

Summary of Contents for DEL 18 Plus

Page 1: ...NSTALACJA Elektronisch geregelter Komfort Durchlauferhitzer Electronically controlled comfort instantaneous water heater Chauffe eau instantan confort r gulation lectronique Elektronisch geregelde com...

Page 2: ...10 1 Standard installation 30 11 Commissioning 31 11 1 Preparation 31 11 2 Initial start up 32 11 3 Recommissioning 32 12 Appliance shutdown 32 13 Alternative installation methods 32 13 1 Electrical c...

Page 3: ...must be connected to the earth conductor The appliance must be permanently connected to fixed wiring Secure the appliance as described in chapter In stallation Installation Observe the maximum permiss...

Page 4: ...n or persons with limited physical sensory or men tal abilities are allowed to use this appliance we recommend a permanent temperature limit The following limitation options are available User adjusta...

Page 5: ...C 1 C Note If the outlet temperature is not high enough when the draw off valve is fully open and the temperature selector is set to maximum then more water is flowing through the appliance than can...

Page 6: ...rs maximum precision and maximum convenience in DHW provision Should you nonetheless be operating the appliance with a thermostatic valve we recom mend that you f f Adjust the set temperature on the a...

Page 7: ...te The required temperature cannot be set The high limit safety cut out and or internal anti scalding protection are enabled Disable temperature limiting The internal anti scalding protection can be a...

Page 8: ...tated on the type plate In a linked water net work factor in the lowest electrical resistance of the water Your water supply utility will advise you of the specific elec trical water resistance or con...

Page 9: ...he minimum clearances to ensure trouble free op eration of the appliance and facilitate maintenance work 9 3 Water installation f f Flush the water line thoroughly Taps valves Use appropriate pressure...

Page 10: ...rd delivery f f Fit the wall mounting bracket Installing the twin connector Material losses Carry out all water connection and installation work in accordance with regulations 12 D0000053319 f f Seal...

Page 11: ...that the appliance is earthed Material losses Observe the type plate The specified rated voltage must match the mains voltage f f Connect the power cable to the mains terminal Fitting the lower back p...

Page 12: ...a ballpoint pen to do this f f Secure the appliance cover with the screw f f Fit the fascia to the appliance cover D0000053281 f f Switch on the power supply 11 2 1 Appliance handover f f Explain the...

Page 13: ...further downwards To do this undo the fixing screw Secure the mains terminal in place 13 3 Electrical connection on finished walls Note This type of connection changes the IP rating of the ap pliance...

Page 14: ...nnection pipes to the tee and the 3 way ball shut off valve Note Observe the tap manufacturer s instructions 13 7 Fitting appliance cover over water installation on finished walls D0000073170 4 3 2 1...

Page 15: ...f Turn the appliance cover not the appliance and refit the programming unit Push the programming unit home in par allel until all locking tabs engage When engaging the locking tabs apply counter pres...

Page 16: ...programming unit PCB is faulty Check the programming unit and replace if required Green flashes yellow on red off No DHW the outlet temper ature does not match the set value The downstream tap is fau...

Page 17: ...gral safety switch 2 Bare wire heating system 3 High limit safety cut out 4 Mains terminal Priority control with LR 1 A 85_02_02_0003_ 2 1 1 Control cable to the contactor of the second appliance elec...

Page 18: ...x MPa 0 04 0 08 Thermostatic valve approx MPa 0 03 0 05 Shower head approx MPa 0 03 0 15 Sizing the pipework When calculating the size of the pipework an appliance pressure drop of 0 1 MPa is recommen...

Page 19: ...r reheating C 55 55 Values Max inlet temperature e g pasteurisation C 70 70 ON l min 2 5 2 5 Flow rate at 28 K l min 9 2 10 7 12 3 at 400V 13 8 at 400V Flow rate at 50 K l min 5 2 6 0 6 9 at 400V 7 7...

Page 20: ...STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88...