OPERATION
General information
www.stiebel-eltron-usa.com
Accelera® 220-300 E |
7
EN
GL
ISH
OPERATION
1.
General
information
The chapters “Special information” and “Operation” are intended
for appliance users and qualifi ed contractors.
The chapter “Installation” is intended for qualifi ed contractors.
Note
Read these instructions carefully before using the appli-
ance and retain them for future reference.
Pass on the instructions to a new user if required.
2.
Safety
This chapter provides an overview of all important actions re-
quired for a safe and trouble-free operation.
2.1
Intended
use
The appliance is intended for DHW heating within the application
limits (See 16.3, “Data table”, pg. 33).
The appliance is intended for domestic use, i.e. it can be used
safely by untrained persons. The appliance can also be used in a
non-domestic environment, e.g. in a small business, as long as it
is used in the same way.
Any other use beyond that described shall be deemed inappropri-
ate. Observation of these instructions and of instructions for any
accessories used is also part of the correct use of this appliance.
2.2
Incorrect
use
The following are not permitted:
- Heating liquids other than potable water
- Operating the appliance with an empty DHW tank
- Operating the appliance outside the application limits (See
16.3, “Data table”, pg. 33)
- Interrupting the power supply, as without power supply the
appliance is not protected against corrosion
2.3
General safety instructions
Only qualifi ed contractors should carry out the electrical work and
installation of this appliance. Qualifi ed contractors are responsible
for adherence to all applicable regulations.
Operate the appliance only when fully installed and with all safety
equipment fi tted.
!
WARNING Injury
The appliance may be used by children aged 8 and up and
persons with reduced physical, sensory or mental capa-
bilities or a lack of experience and know-how, provided
that they are supervised or they have been instructed on
how to use the appliance safely and have understood
the resulting risks. Children must never play with the
appliance. Children must never clean the appliance or
perform user maintenance unless they are supervised.
WARNING Electrocution
Contact with live components presents a threat to life.
Damage to the electric insulation or to individual com-
ponents may result in a threat to life.
If there is damage to the insulation, disconnect the
power supply and arrange a repair.
All work on the electrical installation must be carried
out by a qualifi ed contractor.
WARNING Scalding
The water in the DHW tank can be heated to tempera-
tures in excess of 149 °F / 65 °C. There is a risk of scalding
at outlet temperatures in excess of 110 °F / 43 °C.
Ensure you do not come into contact with the water
when discharged.
WARNING Burns
Touching hot components can lead to burns.
When working on hot components, always wear protec-
tive working clothing and safety gloves.
The pipework connected to the DHW outlet of the appli-
ance can reach temperatures in excess of 149 °F / 65 °C.
WARNING Scalding
The appliance is fi lled with refrigerant at the factory.
In case of leaking refrigerant, avoid coming into contact
with the refrigerant or inhaling the released vapors. Ven-
tilate the rooms affected.
!
CAUTION Injury
Never place any objects on top of the appliance. If objects
are left on the appliance, noise emissions may increase
due to resulting vibrations, and the objects could fall
and cause injury.
!
CAUTION
To reduce the risk of excessive pressures and tempera-
tures in this water heater, install temperature and pres-
sure protective equipment required by local codes and
no less than a combination temperature and pressure
relief valve certifi ed by a nationally recognized testing
laboratory that maintains periodic inspection of produc-
tion of listed equipment or materials, as meeting the re-
quirements for Relief Valves and Automatic Gas Shutoff
Devices for Hot Water Supply Systems, ANSI Z21.22. This
valve must be marked with a maximum set pressure not
to exceed the marked maximum working pressure of the
water heater. Install the valve into an opening provided
and marked for this purpose in the water heater, and
orient it or provide tubing so that any discharge from
the valve exits only within 6 inches above, or at any
distance below, the structural fl oor, and does not contact
any live electrical part. The discharge opening must not
be blocked or reduced in size under any circumstances.