HUV  1/2/65/80

instAllAtion 
tecHniscHe dAten

6.  Technische Daten

 

 

HuV 1

HuV 2

HuV 65

HuV 80

 

 

227420

223391

227425

227426

Schallangaben
Schallleistungspegel

dB(A)

35

45

45

35

Einsatzgrenzen
Max. zulässiger Druck

MPa

276

276

60

60

Hydraulische Daten
Kvs-Wert

m

3

/h

26

49

58

90

Differenzdruck Δp

max

kPa

100

350

140

80

Schließdruck Δp

s

kPa

1000

1400

140

80

Elektrische Daten
Nennspannung

V

230

230

230

230

Frequenz

Hz

50/60

50/60

50/60

50/60

Leistungsverbrauch Betrieb

W

1,5

2,5

2

2

Leistungsverbrauch Ruhestellung

W

0,4

0,4

1

1

Leistungsverbrauch Dimensionierung

VA

 

 

4,5

4,5

Ausführungen
Elektroanschlusskabel

 

*

*

*

*

Elektroanschlusskabel Länge ca.

mm

1000

1000

1000

1000

Betriebsart

 

parallel

parallel

parallel

parallel

Schutzklasse

 

II, schutzisoliert

II, schutzisoliert

II, schutzisoliert

II, schutzisoliert

Schutzart (IP)

 

IP54

IP54

IP54

IP54

Dimensionen
Länge

mm

84,5

131,5

290

310

Gewichte
Gewicht

kg

1,65

4,8

16,3

22,5

Werte
Zulässiges Medium

 

H

2

O

H

2

O

H

2

O

H

2

O

Zulässiges Medium 2

 

H

2

O Glykol S

H

2

O Glykol S

H

2

O Glykol S

H

2

O Glykol S

Maximales Mischverhältnis

%

50

50

50

50

Zulässiger Medium-Zusatz

 

Glykol

Glykol

Glykol

Glykol

Max. Betriebstemperatur

°C

100

100

100

100

Durchfluss Regelpfad A-AB (VDi 2173)

n(gL)

3,9

3,9

3

3

Durchfluss Bypass B-BA (linear)

 

kvs * 0,7

kvs * 0,7

 

 

Leckrate Bypass B-AB

 

kvs * 0,01

kvs * 0,01

kvs * 0,01

kvs * 0,01

Leckrate Regelpfad A-AB (B0,1 Din 3230)

 

luftblasendicht

luftblasendicht

 

 

Drehwinkel

°

90

90

 

 

Drehwinkel Arbeitsbereich

°

15...90

15...90

 

 

Anschlusskabel Kabelquerschnitt

mm

2

 

 

3 x 0,75

3 x 0,75

Drehmoment

Nm

min. 5

min. 20

 

 

Laufzeit

 

90s / 90°

90s / 90°

7,5 s/mm (18mm)

7,5 s/mm (18mm)

Umgebungstemperatur

°C

0...50

0...50

0...50

0...50

Zulässige relative Raumfeuchte (nicht kondensierend)

%

95

95

95

95

Summary of Contents for 223391

Page 1: ...d Installation Operating and installation Utilisation et Installation Gebruik en Installatie 3 Wege Umschaltventil 3 way switching valve Soupape d inversion 3 voies Drieweg omschakelklep HUV 1 HUV 2 H...

Page 2: ...ingewiesenen Personen sicher bedient wer den In nicht h uslicher Umgebung z B im Kleingewerbe kann das Ger t ebenfalls verwendet werden sofern die Benutzung in gleicher Weise erfolgt 2 2 Sicherheitshi...

Page 3: ...ngt die Kugel des 3 Wege Umschalt ventil die als Drossel wirkt in die vom Stellsignal vorgegebene Stellung Das Ventil ffnet sich durch Drehung im Uhrzeigersinn und schlie t sich bei Drehung gegen den...

Page 4: ...Einbaulagen 90 90 C26_03_01_0998 4 2 Hydraulische Einbindung Besch digungsgefahr Die Bestimmungen gem VDI 2035 bez glich der Was serqualtit t sind einzuhalten Damit die 3 Wege Um schaltventile langfr...

Page 5: ...u Steuerung a b 1 2 3 N L a a b b D0000043142 1 blau 2 braun 3 wei 5 Wartung Die 3 Wege Umschaltventile mit eingebautem Stellantrieb sind wartungsfrei Sie enthalten keine durch den Anwender austausch...

Page 6: ...rt II schutzisoliert II schutzisoliert II schutzisoliert Schutzart IP IP54 IP54 IP54 IP54 Dimensionen L nge mm 84 5 131 5 290 310 Gewichte Gewicht kg 1 65 4 8 16 3 22 5 Werte Zul ssiges Medium H2O H2O...

Page 7: ...deutsch HUV 1 2 65 80 7 Notizen...

Page 8: ...eile werden unser Eigentum F r die Dauer und Reichweite der Garantie bernehmen wir s mt liche Material und Montagekosten Soweit der Kunde wegen des Garantiefalles aufgrund gesetz licher Gew hrleistung...

Page 9: ...e in Deutschland Entsorgung von Altger ten in Deutschland Ger teentsorgung Die mit diesem Symbol gekennzeichneten Ger te d r fen nicht mit dem Hausm ll entsorgt werden Als Hersteller sorgen wir im Rah...

Page 10: ...ong as it is used in the same way 2 2 Safety instructions Observe the following safety instructions and regula tions Heat pump systems and accessories may only be installed by a recognised specialised...

Page 11: ...al The valve opens by turning clockwise and closes by turning anticlockwise factory setting HUV 65 HUV 80 only The lift drives are regulated by a 3 point control system and move the closing element wh...

Page 12: ...he tappet facing down Permissible installation positions 90 90 C26_03_01_0998 4 2 Hydraulic connection Beware of damage The conditions in VDI 2035 regarding water quality must be complied with So that...

Page 13: ...tion diagram open closed control a b 1 2 3 N L a a b b D0000043142 1 blue 2 brown 3 white 5 Maintenance The 3 way switching valves with integrated servo drive require no maintenance They do not contai...

Page 14: ...ed II double insulated II double insulated IP rating IP54 IP54 IP54 IP54 Dimensions Length mm 84 5 131 5 290 310 Weights Weight kg 1 65 4 8 16 3 22 5 Values Permissible medium H2O H2O H2O H2O Permissi...

Page 15: ...ssued by those subsidiaries Such warranties are only granted if the subsidiary has issued its own terms of warranty No other warranty will be granted We shall not provide any warranty for appliances a...

Page 16: ...echniques particuli res L appareil peut galement tre utilis dans un environnement non domestique p ex dans des petites entreprises condition que son utilisation soit du m me ordre 2 2 Consignes de s c...

Page 17: ...e de la soupape d inversion trois voies qui joue le r le de restricteur dans la position indiqu e par le signal de commande Une rotation dans le sens des aiguilles d une montre permet d ouvrir la soup...

Page 18: ...poussoir vers le bas Positions de montage autoris es 90 90 C26_03_01_0998 4 2 Int gration hydraulique Risque d endommagement Les prescriptions de VDI 2035 concernant la qualit de l eau doivent tre re...

Page 19: ...uverture fermeture a b 1 2 3 N L a a b b D0000043142 1 bleu 2 marron 3 blanc 5 Maintenance Les soupapes d inversion 3 voies avec m canisme de commande int gr ne n cessitent aucune maintenance Elles ne...

Page 20: ...ction II double isolation II double isolation II double isolation II double isolation Indice de protection IP IP54 IP54 IP54 IP54 Dimensions Longueur mm 84 5 131 5 290 310 Poids Poids kg 1 65 4 8 16 3...

Page 21: ...rantie ne pourra cependant tre accord e que si la filiale a publi ses propres conditions de garantie Il ne sera accord aucune garantie par ailleurs Nous n accordons aucune garantie pour les appareils...

Page 22: ...ng Het kan veilig worden bediend door personen die daarover niet ge nstrueerd zijn Het toestel kan eventueel ook buiten een huishouden gebruikt worden bijv in het kleinbedrijf voor zover het op dezelf...

Page 23: ...aangestuurd en zet de bol van de drieweg omschakelklep die als regelklep werkt in de door het stelsignaal aangegeven stand De klep opent door met de klok mee te draaien en sluit door tegen de klok in...

Page 24: ...osities 90 90 C26_03_01_0998 4 2 Hydraulische verbinding Gevaar voor beschadiging De bepalingen van VDI 2035 met betrekking tot de water kwaliteit moeten in acht worden genomen Het gebruik van vuilfil...

Page 25: ...UV 80 Aansluitschema open sluitsturing a b 1 2 3 N L a a b b D0000043142 1 blauw 2 bruin 3 wit 5 Onderhoud De drieweg omschakelkleppen met ingebouwde stelaandrijving zijn onderhoudsvrij Ze hebben geen...

Page 26: ...randgeaard II randgeaard II randgeaard Beschermingsgraad IP IP54 IP54 IP54 IP54 Afmetingen Lengte mm 84 5 131 5 290 310 Gewichten Gewicht kg 1 65 4 8 16 3 22 5 Waarden Toegestaan medium H2O H2O H2O H...

Page 27: ...appij Een dergelijk garantie wordt alleen verstrekt wanneer de dochtermaatschappij eigen garantievoorwaarden heeft gepubliceerd In andere situaties wordt er geen garantie verleend Voor toestellen die...

Page 28: ...ergissingen en technische wijzigingen Salvo error o modificaci n t cnica R tt till misstag och tekniska ndringar f rbeh lls Excepto erro ou altera o t cnica Zastrze one zmiany techniczne i ewentualne...

Reviews: