Page 1: ...OPERATION AND INSTALLATION Floorstanding DHW cylinder SBB 302 WP AU SBB 401 WP SOL AU SBB 501 WP SOL AU ...

Page 2: ...ilure to observe this information may result in non seri ous or minor injury OPERATION 1 General information 2 1 1 Further applicable documents 2 1 2 Safety instructions 2 1 3 Other symbols in this documentation 3 1 4 Units of measurement 3 2 Safety 3 2 1 Intended use 3 2 2 Safety instructions 3 2 3 Test symbols 3 3 Appliance description 3 4 Cleaning care and maintenance 4 4 1 Signal anode consump...

Page 3: ...onversions to the appliance void all warranty rights 2 2 Safety instructions WARNING Burns There is a risk of scalding at outlet temperatures in ex cess of 43 C WARNING Injury The appliance may be used by children aged 8 and up and persons with reduced physical sensory or mental capabilities or a lack of experience provided that they are supervised or they have been instructed on how to use the ap...

Page 4: ...ble des caling agents 5 Troubleshooting Telephone your contractor To facilitate and speed up your enquiry please provide the serial number from the type plate 000000 0000 000000 No 000000 0000 000000 Made in Germany D0000080572 INSTALLATION 6 Safety Only a qualified contractor should carry out installation commis sioning maintenance and repair of the appliance 6 1 General safety instructions We gu...

Page 5: ...wer and upper indirect coils WRV 32 part number 232628 SBB WP AU SBB WP SOL AU must only be connected to spec ified heat pumps and solar pump assemblies see chapter Spec ification Heat sources 8 Preparations 8 1 Installation site Always install the appliance in a room free from the risk of frost and near the draw off point Ensure the floor offers sufficient stability see chapter Specifica tion Dat...

Page 6: ...under floor heating systems which are permeable to oxygen In underfloor heating systems with plastic pipes that are per meable to oxygen and in open vented heating systems oxygen diffusion may lead to corrosion on the steel components of the heating system e g on the indirect coil of the DHW cylinder on buffer cylinders steel heating elements or steel pipes Material losses The products of corrosio...

Page 7: ...low off aperture of the safety valve must remain open towards the atmosphere f f Fit the blow off line of the safety assembly with a constant slope f f Observe the information in the installation instructions of the safety assembly 9 5 Fitting the thermometer and DHW sensor 26_03_20_0005 1 1 Thermometer f f Insert the thermometer as far as it will go and align it f f Insert the DHW sensor into the...

Page 8: ...e cylinder needs to be drained for maintenance or to protect the whole installation when there is a risk of frost proceed as follows f f Close the shut off valve in the cold water line f f Open the hot water taps on all draw off points f f Drain the appliance via the drain valve of the safety assembly 13 3 Replacing the signal anode f f Replace the signal anode if it becomes depleted Ensure there ...

Page 9: ...et Male thread G 1 A c03 Cold water inlet pipe Male thread G 1 A Torque nm 100 c06 DHW outlet Male thread G 1 A c10 DHW circulation Male thread G 1 2 A c13 T P valve Female thread Rp 3 4 d07 Heat pump heating flow Female thread G 1 1 2 d08 Heat pump heating return Female thread G 1 1 2 h05 Sensor heat pump DHW Diameter mm 9 5 h06 Sensor heat pump DHW optional Diameter mm 9 5 h43 Thermometer Diamet...

Page 10: ...A Torque nm 100 c06 DHW outlet Male thread G 1 A c10 DHW circulation Male thread G 1 2 A c13 T P valve Female thread Rp 3 4 d07 Heat pump heating flow Female thread G 1 1 2 d08 Heat pump heating return Female thread G 1 1 2 d25 Solar flow Female thread G 1 1 2 d26 Solar return Female thread G 1 1 2 h05 Sensor heat pump DHW Diameter mm 9 5 h06 Sensor heat pump DHW optional Diameter mm 9 5 h28 Senso...

Page 11: ...ld water inlet pipe Male thread G 1 A Torque nm 100 c06 DHW outlet Male thread G 1 A c10 DHW circulation Male thread G 1 2 A c13 T P valve Female thread Rp 3 4 d07 Heat pump heating flow Female thread G 1 1 2 d08 Heat pump heating return Female thread G 1 1 2 d25 Solar flow Female thread G 1 1 2 d26 Solar return Female thread G 1 1 2 h05 Sensor heat pump DHW Diameter mm 9 5 h06 Sensor heat pump DH...

Page 12: ...ttom hPa 17 17 Mixed water volume 40 C 15 C 60 C l 514 681 857 Application limits Max permissible pressure MPa 1 00 1 00 1 00 Test pressure MPa 1 50 1 50 1 50 Max permissible temperature C 95 95 95 Max throughput l min 38 45 50 Max recommended collector aperture area m 8 10 Energy data Standby energy consumption 24 h at 65 C kWh 2 10 2 40 2 40 Values T P valve nominal set temperature C 99 99 99 T ...

Page 13: ...02 WP AU SBB 401 WP SOL AU and SBB 501 WP SOL AU the unit 3 Subject to the warranty exclusions we will repair or re place at our absolute discretion a faulty component in your unit free of charge if it fails to operate in accordance with its specifications during the warranty period 4 If we repair or replace a faulty component to your unit under this warranty the warranty period is not extended fr...

Page 14: ...with you to inspect and test the unit Warranty exclusions 12 We may reject your warranty claim if 12 1 The unit was not installed by registered and qualified tradespeople 12 2 The unit was not installed and commissioned a in Australia b in accordance with the Operating and Installation Guide and c in accordance with the relevant statutory and local requirements of the State or Territory in which t...

Page 15: ...orised service technician may refuse to inspect and test the unit until you provide safe and free access to it at your cost 16 If we reject your warranty claim in accordance with clause 12 we may charge you for our authorised service techni cian s labour costs to inspect and test the unit 17 In order to properly test the unit we may remove it to an other location for testing Australian Consumer La...

Page 16: ...tiebel eltron cz www stiebel eltron cz Finland STIEBEL ELTRON OY Kapinakuja 1 04600 Mäntsälä Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz Cédex 3 Tel 0387 7438 88 Fax 0387 7468 26 info stiebel eltron fr www stiebel eltron fr Hungary STIEBEL ELTRON Kft Gyár u 2 2040 Budaörs Tel 01 250 6055 Fax 01 368 8097 info stie...