FLX-E Operations Manual Rev F
Page 49
Table of Contents
Top
Byte 2 = 0x00
high byte of payload length
Byte 3 = 0xXX
message sequence number
Byte 4 = 0x52
command code
Byte 5 = 0xXX
channel number
Byte 6 = 0x01
mute state is on
Byte 7 = 0xXX
8-bit sum of bytes 1 through 6
18.
DECREASE PREMIX ATTENUATION 3 dB
Command code: 0x54
Description: command used to decrease system premix attenuation by 3 dB
Input parameters –
Parameter 1 - 8-bit channel number, 0 = all channels, 1...8 is single channel
Host sent data
Byte 0 = 0x1E
start of message character
Byte 1 = 0x03
low byte of payload length
Byte 2 = 0x00
high byte of payload length
Byte 3 = 0xXX
message sequence number
Byte 4 = 0x54
command code
Byte 5 = 0xXX
channel number
Byte 6 = 0xXX
8-bit sum of bytes 1 through 5
FLX-E Response
Byte 0 = 0x1E
start of message character
Byte 1 = 0x03
low byte of payload length
Byte 2 = 0x00
high byte of payload length
Byte 3 = 0xXX
message sequence number
Byte 4 = 0x54
command code
Byte 5 = 0xXX
command response, 0 = error, 1 = success
Byte 6 = 0xXX
8-bit sum of bytes 1 through 5
19.
INCREASE PREMIX ATTENUATION 3 dB
Command code: 0x55
Description: command used to increase system premix attenuation by 3 dB
Input parameters –
Parameter 1 - 8-bit channel number, 0 = all channels, 1...8 is single channel
Host sent data
Byte 0 = 0x1E
start of message character
Byte 1 = 0x03
low byte of payload length
Byte 2 = 0x00
high byte of payload length
Byte 3 = 0xXX
message sequence number
Byte 4 = 0x55
command code