70.7V Speaker Line (length in feet)
Wire
gauge
7.5W
Load
15W
Load
30W
Load
60W
Load
100W
Load
125W
Load
250W
Load
400W
Load
500W
Load
10
20,000
10,000
5,000
2,500 1,500 1,100
550
365
275
12
12,400
6,200
3,100
1,550
940
750
375
230
185
14
7,600
3,800
1,900
950
600
450
225
140
110
16
4,800
2,400
1,200
600
370
290
145
90
X
18
3,000
1,500
750
375
230
180
90
X
X
20
1,920
960
480
240
150
110
X
X
X
22
1,200
600
300
150
95
X
X
X
X
100V Speaker Line (length in feet)
Wire
gauge
7.5W
Load
15W
Load
30W
Load
60W
Load
100W
Load
125W
Load
250W
Load
400W
Load
500W
Load
10
40,000
20,000
10,000
5,000 3,000 2,200 1,100
730
550
12
24,800
12,400
6,200
3,100 1,880 1,500
750
460
370
14
15,200
7,600
3,800
1,900 1,200
900
450
280
220
16
9,600
4,800
2,400
1,200
740
580
290
180
X
18
6,000
3,000
1,500
750
460
360
180
X
X
20
3,840
1,920
960
480
300
220
X
X
X
22
2,400
1,200
600
300
190
X
X
X
X
Shaded cells indicate a violation of the Maximum Current Rating in the National Electrical Code (NEC) and
must not be used.