19
7.
INSPECTION AND MAINTENANCE
7.1 GENERAL
During inspection and maintenance the car lift should be in the lowest position and the main switch should
be turned off. This means that the main switch should be turned to the 0 position and is to be secured with a
padlock.
The current should be turned on again only for the adjustments and checks that require it.
Lubrication chart
The car lift must be regularly serviced as listed.
Once a year the lift must be subjected to a highly detailed check and inspection.
You can have the car lift professionally checked by STERTIL mechanics by entering into a
maintenance contract.
Maintenance and inspection
Description
Monthl
y
yearly
Cylinder
Lubricate dry piston rod (machine oil)
X
Check oil level in reservoir
Top up (with car lift at ground level only)
X
Several pivot points
Grease
X
HYDRAULIC OIL
It is strongly recommended that the hydraulic oil be changed at least every 2 years, irrespective
of the amount of use to which the lift is subjected.
OIL CHANGING
1. Lower lift to fullest extent and drain all the oil.
2. Refill with hydraulic oil UNIL HVC S15, filtered at 4 micron max.
Model
ST 1055
ST 1060
ST 1072
Litre
7
Lubrication chart
7.2
DAILY (BY OPERATOR)
- Check for visible damage.
- Check for oil leaks in the hydraulic unit, lines and cylinder.
7.3
MONTHLY (BY OPERATOR)
Check hydraulic fluid level, and replenish as necessary.
- Remove the cover from the hydraulic unit. Ensure that the column is in its lowest position and check the oil level
in the plastic tank; the level must between the two horizontal marks.
- Fill up with UNIL HVC S15, filtered on 4 microns, up to the end of the dipstick.
Check the emergency release mechanism.
- Push the emergency release button when the columns are moving. All the columns should stop immediately.
- To release the emergency stop button turn it counter-clockwise, set the main switch(es) to O and then to 1 and
press the "SET REF"-button to restore control power.
Summary of Contents for ST 1055
Page 1: ...Mobile Column Lifts ST 1055 ST 1060 ST 1072 Installation operation service 325 58 990A ...
Page 2: ......
Page 5: ......
Page 34: ...29 FIG A ...
Page 36: ...31 FIG B ...
Page 40: ...35 FIG F ELECTRICAL DIAGRAM CONTROLBOX PRIMARY ...
Page 42: ...37 FIG H ELECTRICAL DIAGRAM SECONDARY COLUMN ...
Page 47: ...42 FIG M DIMENSIONAL DRAWING ST 1072 ST 1055 ST 1060 ST 1072 V widened model 27 49 ...
Page 49: ......