13
5.2
CONNECTING LIFTING COLUMNS
A fully closed ring circuit consists of a minimum of two and a maximum of 32 lifting columns (single phase a min.
of 2 and a max. of 4 lifting columns).
A column circuit requires at least 1 (one) primary column. The position of a primary column in a circuit is
irrelevant, but preferably should be located near the power supply. If in a column circuit there is one primary
column, this circuit is called a "set".
A set can consist of 2, 3, 4, 5 or 6 etc. up to 32 lifting columns (single phase 2, 3 or max. 4 lifting columns).
A set has a maximum lifting capacity of 40,000/48,000/64,000 lbs (this is the maximum lifting capacity of a standard
set of 4 lifting columns of 10,000/12,000/16,000 lbs each). For higher lifting capacities, "sets" are to be combined in
a column circuit as specified in the table below (also see fig. 5.2).
3 Phase
Lifting capacity in lbs
Minimum
number of
primary
columns
Maximum
number of
secondary
columns
up to 40,000
up to 48,000
up to 64,000
1
5
40,000 to 80,000
48,000 to 96,000
64,000 to 128,000
2 (2 sets required)
10
80,000 to 120,000
96,000 to 144,000
128,000 to 192,000
3 (3 sets required)
15
120,000 to 160,000
144,000 to 192,000
192,000 to 256,000
4 (4 sets required)
20
etc. etc. etc.
etc.
etc.
1 Phase
Lifting capacity in lbs
ST 1055
ST 1060
ST 1072
Minimum number
of primary
columns
Maximum
number of
secondary
columns
up to 40,000 lbs
up to 48,000 lbs
up to 64,000 lbs
2
2
Primary columns are arranged in a circuit so that the weight of the load of the "set" (primary column followed by the
secondary columns up to the next primary column) does not exceed 40,000/48,000/64,000 lbs. To increase the
flexibility of a system, it is possible to select a primary column as a secondary column.
To ensure safety, each primary column is provided with a thermal relay preventing a set from being overloaded and
protecting the lifting system against power overloads.
Summary of Contents for ST 1055
Page 1: ...Mobile Column Lifts ST 1055 ST 1060 ST 1072 Installation operation service 325 58 990A ...
Page 2: ......
Page 5: ......
Page 34: ...29 FIG A ...
Page 36: ...31 FIG B ...
Page 40: ...35 FIG F ELECTRICAL DIAGRAM CONTROLBOX PRIMARY ...
Page 42: ...37 FIG H ELECTRICAL DIAGRAM SECONDARY COLUMN ...
Page 47: ...42 FIG M DIMENSIONAL DRAWING ST 1072 ST 1055 ST 1060 ST 1072 V widened model 27 49 ...
Page 49: ......