background image

thermostat then enters into code matching state. After completing the code matching, press the key
again to start the 3

rd

 channel code matching, in which case the indicator will blink in “three flashes

after one stop”. The code matching is then started. Likewise, press the key for the fourth time to start
the 4

th

 channel code matching, in which case the indicator will blink in “four flashes and one stop”.

8.  Fault Display:

When the room temperature is lower than 0 , the LCD will blink in 00.0 . When the room
temperature is higher than 0 , the LCD will resume automatically to normal display.
When the room temperature is higher than 45 , the LCD will blink in 45.0 . When the room
temperature is lower than 45.0 , the LCD will resume automatically to normal display.
Upon disconnection of the temperature sensor, the display will blink in E0.1, in which case you shall
check and eliminate the fault.

9.  Engineering Setting

Hold dwon

  key for 5 seconds under OFF state, The place where the time is displayed will show

the setting number, while the place where the temperature is displayed will show the set parameters.

Press

 or

  to change the parameter setting, and press

  key to enter into next setting. You

may press

  key to confirm and exit the setting of engineering parameters. If no operation of any

key within 60 seconds, it will save and exit, then return to OFF state.

Setting
Number

Notes on
Numbering

Adjustable Range

Three-Digit where
temperature

is

displayed(The value to be
set will blink

Remarks

Temperature

difference

from stop to

restart or

cycles per

hour

Temperature difference

from stop to restart: 0.2

00.2

Temperature difference

from stop to restart: 0.5

00.5

Temperature difference

from stop to restart: 1.0

01.0

Temperature difference

from stop to restart:

1.5 (Default Value)

01.5

Temperature difference

from stop to restart: 2.0

02.0

Temperature difference

from stop to restart: 2.5

02.5

Temperature difference

from stop to restart: 3.0

03.0

Temperature difference

03.5

Summary of Contents for RTW101

Page 1: ... control and energy saving of wall mounted boilers condensation boilers and individual household mearsuring heating system 9 It can realize the function of one receiver controlling many sub devices and many rooms at the same time 10 Display adjustable between C and F 11 Only need 2 size AA 1 5V batteries for the power supply 12 Three transmission modes for selection i e wired wireless or multi cha...

Page 2: ...Key Menu key Power ksy Set key Confirmation key Increasing key Decreasing key Alarm Display 00 0 Flash Actual room temperature lower than 0 45 0 Flash Actual room temperature higher than 45 E0 1 Temperature probe NTC disconnected Product Specifications Power two LR6 1 5V alkaline batteries Range of temperature adjustment 5 35 39 95 Range of temperature display 0 40 32 104 Temperature test frequenc...

Page 3: ...c valve 3 Control of water pump 4 Ventilation control Run Mode 1 Factory Preset Mode In this case the icon displayed on working state column is Factory preset program Monday to Friday 00 00 06 00 Economic temperature 06 00 08 00 Comfortable temperature 08 00 18 00 Antifreeze temperature 18 00 22 00 Comfortable temperature 22 00 24 00 Economic temperature Saturday and Sunday 00 00 06 00 Economic te...

Page 4: ...des Press the key to turn on the thermostat After turnning on the thermostat you may press menu key to switch the run modes between factory preset mode user defined mode manual mode and antifreeze mode Setting During setting the thermostat is temporarily under disconnected state When finishing the setting press the key to confirm if no operation of any key in 60 seconds the thermostat will turn in...

Page 5: ...Antifreeze temperature The setting range of the comfortable temperature is 5 35 the preliminary value is 20 The setting range of the economic temperature is 5 35 the preliminary value is 18 The setting range of the antifreeze temperature is 5 35 the preliminary value is 5 A When you finish the Time setting don t Press key but press key again then it will enter into the Temperature setting The scre...

Page 6: ...completing the setting of temperature state in 24 hours Then return to date selection Under the program setting state for each hour you may long press key to back to last hour setting or press key for long time to directly enter into date selection again The temperature for unset part remains to be the default temperature or the preset temperature E The date icon will start to blink again entering...

Page 7: ...erature directly through key or key the number representing the temperature will flash press key to confirm and stop flashing Without any adjustment in 5 seconds The number representing the temperature will stop flashing and continuously to display the present room temperature The thermostat will recover to automatic mode at the following program temperature changes 7 Code Matching Only used for R...

Page 8: ...lt 9 Engineering Setting Hold dwon key for 5 seconds under OFF state The place where the time is displayed will show the setting number while the place where the temperature is displayed will show the set parameters Press or to change the parameter setting and press key to enter into next setting You may press key to confirm and exit the setting of engineering parameters If no operation of any key...

Page 9: ...lay for the first two digits 1 Energy saving State No display for the first two digits 2 Switch between and Display in Default No display for the first two digits 0 Display in No display for the first two digits 1 Keypad Keypad not activated Default No display for the first two digits 0 Lock SET key No display for the first two digits 1 Lock all keys No display for the first two digits 2 Highest t...

Page 10: ...n special treatment has been made to the program Therefore it is normal that the thermostat cannot immediately display the sudden change of temperature 2 The thermostat installed in standard 86 box shall be placed 1 5m above the ground 3 For the thermostat installed in standard 86 box or wireless thermostat with battery seat take care not to install it to the wall corner door window side or behind...

Page 11: ... 3 NC Normally Closed point 2 Symbol Illustration B Wall Mounted Gas Boiler U Water Pump Thermal Actuator or electromagnetic valve 3 Control Illustration Fig 2 Dimensional Diagram Length Width Thickness Installing Size RTW101 Fig 3 Control of Wall mounted Boiler for RTW101 model Fig 4 Control of Wall mounted Boiler for WH701RF WH711RF mode ...

Page 12: ...Fig 5 Control of Water Pump Thermal Actuator or electromagnetic valve for RF model ...

Reviews: