 Fault Repair

Problem

Possible Cause

How to Repair

The thermostat does not work  1. Not  connected to power

supply.

1.Battery seat: Check if the battery
contact is in good condition.

The heating system cannot be
started.

2. If the preset temperature is
higher than the temperature
currently on display.

2. Adjust the preset temperature
higher.

The mode switch doe not work.  3.  Check  if  the  keypad  is

locked.
4. Check if the unit is stopped.

3.Enter engineering setting and
change the keypad lock mode of
number 4.
4.Start the unit.

The Up, Down or OK key does
not work.

5. Check if the keypad is
locked.
6. Check if the unit is stopped.

5.Enter engineering setting and
change the keypad lock mode of
number 4.
6.Start the unit.

The room temperature
displayed on the screen is not
compliant with the actual
temperature.

7. If the equipment is under

run state.

8. If set to temperature
calibration.

7. If the equipment is running,
indicating that the temperature is in the
process of heating / cooling. The two
temperatures will be equal when the
equipment finishs operation.
8. Change the Adjustment
Temperature Setting

Cautions on Installation and Use:

1.  To prevent the thermostat display from a high fluctuation, special treatment has been made to the

program. Therefore, it is normal that the thermostat cannot immediately display the sudden change
of temperature.

2.  The thermostat installed in standard 86 box shall be placed 1.5m above the ground.
3.  For the thermostat installed in standard 86 box or wireless thermostat with battery seat, take care not

to install it to the wall corner, door / window side or behind the door or in such unheated area as
exterior wall. Avoid hot / cold air duct, radiator, flue or thermal pipe.

4.  If the wireless thermostat with battery seat is placed at a position where the air ventilation is poor, the

temperature displayed on the thermostat might be inconsistent to the indoor average temperature.

5.  Only the professional technicians are permitted to open the transmitting and receiving box of the

thermostat for installation. When installing the power supply, make sure that the power cable is well
insulated.

6.  To install the receiving box, please install the base plate firstly and then connect the power and

signal wire correctly before installing the upper cover and fix it. The thermostat is unrepairable
product. The user shall not open the internal circuit board.

7.  Before installing the thermostat, make sure that the system is disconnected. The maximum voltage

of the system shall meet the requirements specified in the Instruction Manual (Max. AC Voltage:
250V).

Summary of Contents for RTW101

Page 1: ... control and energy saving of wall mounted boilers condensation boilers and individual household mearsuring heating system 9 It can realize the function of one receiver controlling many sub devices and many rooms at the same time 10 Display adjustable between C and F 11 Only need 2 size AA 1 5V batteries for the power supply 12 Three transmission modes for selection i e wired wireless or multi cha...

Page 2: ...Key Menu key Power ksy Set key Confirmation key Increasing key Decreasing key Alarm Display 00 0 Flash Actual room temperature lower than 0 45 0 Flash Actual room temperature higher than 45 E0 1 Temperature probe NTC disconnected Product Specifications Power two LR6 1 5V alkaline batteries Range of temperature adjustment 5 35 39 95 Range of temperature display 0 40 32 104 Temperature test frequenc...

Page 3: ...c valve 3 Control of water pump 4 Ventilation control Run Mode 1 Factory Preset Mode In this case the icon displayed on working state column is Factory preset program Monday to Friday 00 00 06 00 Economic temperature 06 00 08 00 Comfortable temperature 08 00 18 00 Antifreeze temperature 18 00 22 00 Comfortable temperature 22 00 24 00 Economic temperature Saturday and Sunday 00 00 06 00 Economic te...

Page 4: ...des Press the key to turn on the thermostat After turnning on the thermostat you may press menu key to switch the run modes between factory preset mode user defined mode manual mode and antifreeze mode Setting During setting the thermostat is temporarily under disconnected state When finishing the setting press the key to confirm if no operation of any key in 60 seconds the thermostat will turn in...

Page 5: ...Antifreeze temperature The setting range of the comfortable temperature is 5 35 the preliminary value is 20 The setting range of the economic temperature is 5 35 the preliminary value is 18 The setting range of the antifreeze temperature is 5 35 the preliminary value is 5 A When you finish the Time setting don t Press key but press key again then it will enter into the Temperature setting The scre...

Page 6: ...completing the setting of temperature state in 24 hours Then return to date selection Under the program setting state for each hour you may long press key to back to last hour setting or press key for long time to directly enter into date selection again The temperature for unset part remains to be the default temperature or the preset temperature E The date icon will start to blink again entering...

Page 7: ...erature directly through key or key the number representing the temperature will flash press key to confirm and stop flashing Without any adjustment in 5 seconds The number representing the temperature will stop flashing and continuously to display the present room temperature The thermostat will recover to automatic mode at the following program temperature changes 7 Code Matching Only used for R...

Page 8: ...lt 9 Engineering Setting Hold dwon key for 5 seconds under OFF state The place where the time is displayed will show the setting number while the place where the temperature is displayed will show the set parameters Press or to change the parameter setting and press key to enter into next setting You may press key to confirm and exit the setting of engineering parameters If no operation of any key...

Page 9: ...lay for the first two digits 1 Energy saving State No display for the first two digits 2 Switch between and Display in Default No display for the first two digits 0 Display in No display for the first two digits 1 Keypad Keypad not activated Default No display for the first two digits 0 Lock SET key No display for the first two digits 1 Lock all keys No display for the first two digits 2 Highest t...

Page 10: ...n special treatment has been made to the program Therefore it is normal that the thermostat cannot immediately display the sudden change of temperature 2 The thermostat installed in standard 86 box shall be placed 1 5m above the ground 3 For the thermostat installed in standard 86 box or wireless thermostat with battery seat take care not to install it to the wall corner door window side or behind...

Page 11: ... 3 NC Normally Closed point 2 Symbol Illustration B Wall Mounted Gas Boiler U Water Pump Thermal Actuator or electromagnetic valve 3 Control Illustration Fig 2 Dimensional Diagram Length Width Thickness Installing Size RTW101 Fig 3 Control of Wall mounted Boiler for RTW101 model Fig 4 Control of Wall mounted Boiler for WH701RF WH711RF mode ...

Page 12: ...Fig 5 Control of Water Pump Thermal Actuator or electromagnetic valve for RF model ...

Reviews: