Stern TUBULAR 1000 B Installation And Maintenance Manual Download Page 18

16

TROUBLE SHOOTING

 PROBLEM    INDICATOR 

 CAUSE 

           SOLUTION

No water 

coming out 

of the tap:

Water flow 

from spout 

does not 

stop: 

Water flow 

diminished

1.Sensor flashes 

continuously when 

user’s hands are within 

the sensor’s range.
2. Red light in the sensor 

does not flash when 

user’s hands   are within 

the sensor’s range.

3. Red light in the sensor 

flashes when user’s 

hands are within the 

sensor’s range.

1. Sensor flashes when 

user’s hands are within 

the sensor’s range. 
2.  Red light in the 

sensor does  not flash 

when user’s hands 

are within the sensor’s 

Low battery.

1. Range is too short.
2. Range is too long.
3. Battery is completely 

used up 
4. Unit is in “Security Mode”*
5. Sensor is picking up 

reflections from the 

washbasin or another object.
1. Connectors between the 

electronic unit and solenoid 

are disconnected. 
2. Debris or scale in solenoid 

3. The central orifice in the 

diaphragm is plugged or the 

diaphragm is torn
4. The water supply pressure 

is higher than 8 bar.
Debris or scale in diaphragm 

1. Sensor is dirty or covered.

2. Sensor is picking up 

reflections from the 

washbasin or another object.

Filter or aerator is clogged

Replace battery.

Increase the range.
Decrease the range.
The battery must be 

replaced. 

Eliminate cause of 

reflection. 

Connect the electronic 

unit connectors to the 

solenoid.
Unscrew solenoid, pull 

out the plunger and the 

spring from the solenoid 

and clean them. Use 

scale remover material if 

needed. When replacing 

the plunger, please make 

sure that the spring is in 

vertical position. 
Clean the orifice or 

replace diaphragm. 

Reduce the supply water 

pressure.
Clean the orifice or 

replace diaphragm. 

Clean or eliminate case 

of interference.
1. Decrease the range 

or eliminate cause of 

reflection. 

Remove, clean, re-install

* “Security Mode”: If the sensor is covered for more than 90 sec. the faucet will automatically shut off water flow. To 

return to normal operation remove any blockage to re-establish operation.

Summary of Contents for TUBULAR 1000 B

Page 1: ...1 INSTALLATION AND MAINTENANCE GUIDE WALL MOUNTED ELECTRONIC FAUCET WITH MIXER TUBULAR 1000 SERIES TUBULAR 1000 SERIES Tubular 1000 B Tubular 1000 E Tubular 1000 B Box Tubular 1000 E Box...

Page 2: ...000 E 8 11 Tubular 1000 B Box and Tubular 1000 E Box 12 SETTINGS ADJUSTMENT 13 BATTERY REPLACEMENT INSTRUCTIONS To replace the battery at Tubular 1000 B and Tubular 1000 B Box models 14 MAINTENANCE Fi...

Page 3: ...r electricity versions Recommended water pressure Sensor range Minimum sensor range Maximum sensor range Security time Hot water temperature 9V battery or 6 x 1 5 V AA batteries 9V transformer 0 5 8 0...

Page 4: ...B 1000 E Spout and attachments incl electronic unit Tubular base Wall rosette M4x6 setscrew 2 x Solenoids and housings with filters and filter adaptors Power splitter IP 67 Battery box Transformer B V...

Page 5: ...all rosette M4x6 screw TUBULAR 1000 B BOX 1000 E BOX Rigid pipes Box mounting pack incl solenoid valves and filters 4 x Screws Permanent panel Temporary protective cover 2 x Angle supports Battery box...

Page 6: ...o not attempt to install your electronic faucet until you obtain the missing parts Preparation for installation Flush the water supply lines thoroughly before installing the faucet Do not allow dirt T...

Page 7: ...nal nut and the disk 5 Connect the cable leading to the solenoid and the cable leading to the power supply at the spout to those at the Tubular base 6 Insert the flexible hoses from inside the wall th...

Page 8: ...olenoid housings and the water inlets Before proceeding to step 3 check that no objects are in front of the sensor besides the washbasin Remove now the protecting sticker that covers the sensor the so...

Page 9: ...mer wait about 10 seconds in order to allow the system to set the ideal sensor range Then the product will be ready for use 3 Turn on the central water supply Check for leaks Note Tubular includes a s...

Page 10: ...re you want to install the spout 3 Insert theTubular boxthrough the wall Connect the water supply pipe to the nipple at the bottom of the Tubular box Installation instructions for TUBULAR 1000 B BOX T...

Page 11: ...you cut it 7 Assemble the temporary panel to the Tubular box 8 Once the works on electricity plumbing and tiles have been finished cut the temporary protective cover at the proper mark at the wall le...

Page 12: ...t automatically Check that no objects are in front of the sensor besides the washbasin Remove now the protecting sticker that covers the sensor Step 2 Connecting the power source 1 If your model is Tu...

Page 13: ...of the water stream simply move the adjustable tilting plate by pressing it smoothly 3 If the automatically adjusted sensor range is not satisfactory to your purposes please refer to the section entit...

Page 14: ...crease detection range and to decrease the detection range of the sensor Adjusting other settings with the remote control Flow time Security time Press to increase the security time and to decrease it...

Page 15: ...box 2 For Tubular 1000 B Box Release the screws at the panel and remove it The battery box is located behind the panel Open carefully the battery s box and replace the used battery with a new 9V batt...

Page 16: ...solenoid valves by opening the nuts c Remove the filters and wash them under running water d Reassemble the filters e Reassemble the solenoid valves f Turn on the regulating valve and adjust the flow...

Page 17: ...ttery box for 1 x 9V battery IP67 Transformer box with transformer Transformer junction box Transformer junction box exit with 3 meter cable and male connector Mixing valve Cat No 07220056 Cat No 0750...

Page 18: ...4 The water supply pressure is higher than 8 bar Debris or scale in diaphragm 1 Sensor is dirty or covered 2 Sensor is picking up reflections from the washbasin or another object Filter or aerator is...

Page 19: ...may arise see Stern Warranty The guarantee does not cover faults or damage caused by incorrect installation and or maintenance wear and tear battery or water composition This includes but is not limi...

Page 20: ...18 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 07 09 015350800...