BATTERY REPLACEMENT

Battery models only 

When the battery weakens, the red indicator light will blink at a constant rate when the 

user’s hands are within the sensor range. The battery must be replaced within two weeks. 
To replace the battery in battery models: 
1. Carefully open the battery box, use a 2.5 mm Allen key
2. Remove the old batteries
3. Replace the used batteries with new D batteries 
4. Close the box.

NOTE:

 Do not mix used batteries with new ones.

IMPORTANT:

 Spent batteries should not be disposed of with normal 

household waste. Contact your local authority for information on waste 

disposal and recycling. 

REMOTE CONTROL FUNCTIONS 

If you acquired the remote control together with your soap dispenser, you may adjust 

the dispenser settings if required. To use the remote control hold it straight in front of 

the sensor at a distance of about 10-15 cm (4-6”).
Attention: The remote control held out of the recommended range (too close or too far) 

will not operate.
The remote control can be used to adjust the following functions:

  1-SOAP QUANTITY

The 1-4 drop keys allow the user to choose the desired soap quantity. 

*

4

2.1 to 2.3 

3

1.6 to 1.9 

2

1.2 to 1.6

1

0.7 to 0.9

Indication: continuous blinking of the LED in the sensor eye.

*The exact dosage depends on soap viscosity.

2

3

1

4

  2-ADJ

This function resets the sensor back to factory 

settings.  

Indication: 2 blinks of the LED in the sensor eye.

  

3-TEMPORARY OFF FUNCTION

This  function is ideal to perform any kind of activity 

in front of the sensor without operating the system 

(for example, cleaning).  The soap dispenser will 

remain shut for one minute when this button is 

pressed once.  

To cancel this function and to return to normal 

operation press the On/Off button again or wait for 

one minute.
Indication: OFF – 2 fast blinks, ON – 4 fast blinks

 

 

4-FILL THE SOAP TANk

Once the soap tank has been filled / re-filled, press 

the FILL button. The pump will run for one minute 

for priming the soap to the soap dispenser spout. 
To stop this activity press the FILL button again. If 

the soap has not started coming out of the spout, 

press the Fill button again.

Summary of Contents for 07292271

Page 1: ...1 TOUCH FREE WALL MOUNTED SOAP DISPENSERs I n sta l l at i o n a n d m a i n t e n a n c e g u i d e EXTREME CS SD EXTREME CS SD 2030...

Page 2: ...9 customizable by optional remote control Preset sensor range 80 mm 10 mm 3 15 0 39 EXTREME CS SD B 237891 EXTREME CS SD E 237890 MF Extreme CS SD E 07292271 EXTREME CS SD 2030B 237896 EXTREME CS SD 2...

Page 3: ...smooth operation of your dispenser If needed use a viscometer to verify the viscosity of your soap to ensure maximum benefit The recommended range for liquid soap viscosity is 100 3800 cPs Thicker li...

Page 4: ...CS SD 2030B E MF Extreme CS SD E 12V Transformer 1 X quick connection fitting 2 x Screws 3 5x1 1 4 1 x pump assembly 1 x Body assembly 1 x Body assembly 1 x Soap tank with bottle support and pump ass...

Page 5: ...the desired location installation EXTREME CS SD B E EXTREME CS SD B E installation 3 Connect the soap tube that is coming out of the soap dispenser body to the quick connector at the top of the soap...

Page 6: ...EME CS SD B E installation Step 1 Installing the EXTREME CS SD 2030B E 1 Cut an adequate opening in the wall for the dimensions of the soap dispenser base where you want to install the spout and the c...

Page 7: ...R tothe soAP DISPENSER 3 Wait about 10 seconds before you put your hands within the sensor range to avoid entering the adjustment mode O RING VISIBLE NOT CONNECTED PROPERLY ONLY THE GROOVES ARE VISIBL...

Page 8: ...far will not operate The remote control can be used to adjust the following functions 1 SOAP QUANTITY The 1 4 drop keys allow the user to choose the desired soap quantity 4 2 1 to 2 3 3 1 6 to 1 9 2 1...

Page 9: ...correct installation inversions of supply pipes Pressures or temperatures exceeding recommended limits Improper manipulation tampering bad or lapsed maintenance Foreign bodies dirt or scale introduced...

Page 10: ...have not resolved this issue replace with appropriate sensor For part numbers see spare parts list Damaged sensor TROUBLESHOOTING Illustration Solution Cause Investigation Indication O RING VISIBLE N...

Page 11: ...18 08 19 01500393 A 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Reviews: