PRE-INSTALLATION INFO

PACk CONTENTS

Familiarize yourself with the part names and ensure that all the parts are included in 

your package. 

Check contents

Separate all parts from the packaging and check each part with the “Pack contents” 

section.
Make sure all parts are accounted for before discarding any packaging material.
If any parts are missing, do not attempt to install your touch free soap dispenser until you 

obtain the missing parts.

Warnings

Do not install the system facing a mirror or any other electronic system operated by an 

infrared sensor.
To prevent reflection problems, it is recommended to keep a minimum distance of 

300 mm between the soap dispenser sensor and any other objects.

Stern liquid soap dispensers, with proper care, will provide long term trouble free

service. Quality liquid soap of recommended viscosity and pH levels are the main factors 

for smooth operation of your dispenser. If needed, use a viscometer to verify the viscosity 

of your soap to ensure maximum benefit. The recommended range for liquid soap 

viscosity is 100-3800 cPs. Thicker liquid soap flows slower and inhibits the pump

valve, causing strain and damage.

Stern liquid soap dispensers are suitable for use with any generic liquid soap of the 

correct viscosity and pH. The pH level of all soap used in Stern liquid soap dispensers 

should be between 6.5 to 8.5. Lower levels will cause corrosion to the metal dispenser 

and even the rubber and plastic components. Higher pH levels will cause swelling to 

rubber parts and degradation of plastic components over time.

IMPORTANT: Keep in mind that when using the faucet installed next to the soap 

dispenser, the user hands should not interfere with the soap dispenser sensor 

detection area.

EXTREME CS SD B / E

1 X quick connection 

fitting

2 x Screws 3.5X1 1/4”

1 x Body assembly

1 x Soap tank with bottle 

support and pump assembly

1 x Battery Box for 6xd alkaline 

batteries \ 12v transformer

B VERSIONS

E VERSIONS

Summary of Contents for 07292271

Page 1: ...1 TOUCH FREE WALL MOUNTED SOAP DISPENSERs I n sta l l at i o n a n d m a i n t e n a n c e g u i d e EXTREME CS SD EXTREME CS SD 2030...

Page 2: ...9 customizable by optional remote control Preset sensor range 80 mm 10 mm 3 15 0 39 EXTREME CS SD B 237891 EXTREME CS SD E 237890 MF Extreme CS SD E 07292271 EXTREME CS SD 2030B 237896 EXTREME CS SD 2...

Page 3: ...smooth operation of your dispenser If needed use a viscometer to verify the viscosity of your soap to ensure maximum benefit The recommended range for liquid soap viscosity is 100 3800 cPs Thicker li...

Page 4: ...CS SD 2030B E MF Extreme CS SD E 12V Transformer 1 X quick connection fitting 2 x Screws 3 5x1 1 4 1 x pump assembly 1 x Body assembly 1 x Body assembly 1 x Soap tank with bottle support and pump ass...

Page 5: ...the desired location installation EXTREME CS SD B E EXTREME CS SD B E installation 3 Connect the soap tube that is coming out of the soap dispenser body to the quick connector at the top of the soap...

Page 6: ...EME CS SD B E installation Step 1 Installing the EXTREME CS SD 2030B E 1 Cut an adequate opening in the wall for the dimensions of the soap dispenser base where you want to install the spout and the c...

Page 7: ...R tothe soAP DISPENSER 3 Wait about 10 seconds before you put your hands within the sensor range to avoid entering the adjustment mode O RING VISIBLE NOT CONNECTED PROPERLY ONLY THE GROOVES ARE VISIBL...

Page 8: ...far will not operate The remote control can be used to adjust the following functions 1 SOAP QUANTITY The 1 4 drop keys allow the user to choose the desired soap quantity 4 2 1 to 2 3 3 1 6 to 1 9 2 1...

Page 9: ...correct installation inversions of supply pipes Pressures or temperatures exceeding recommended limits Improper manipulation tampering bad or lapsed maintenance Foreign bodies dirt or scale introduced...

Page 10: ...have not resolved this issue replace with appropriate sensor For part numbers see spare parts list Damaged sensor TROUBLESHOOTING Illustration Solution Cause Investigation Indication O RING VISIBLE N...

Page 11: ...18 08 19 01500393 A 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Reviews: