11
NARA 2032 P
INSTALLATION
7) Wait about 30 seconds before you step or put your hand within the sensor
range. As an indication that the self adjusting is taking place, a red light in the
sensor eye will flash continuously. The solenoid valve will be opened and closed
for 1 second as an indication that the ideal sensor range was set and the product is
ready for use.
8) To operate, step within the sensor range for a minimum of 8 seconds.
Move away and the flush valve will flush a few seconds after your departure.
9) If needed adjust the flow rate by turning the regulating valve. In order to
avoid entering into the self adjusting mode, do not disconnect the cables
between the electronic unit and battery box.
10) If the range is unsatisfactory, refer to the section entitled
“Settings Adjustment”.
11) Tighten the panel to the cover seat with the bottom screw.
3) Insert the battery into the battery box.
5)
The ideal sensor range for the specific
location will be set automatically. Right
now, check that no objects are in front of
the sensor.
6) Remove the protective sticker covering the
sensor and move away from the sensor range
.
Pay atention, steps 3-6 must be completed within 30 seconds:
30
sec
4) Assemble the panel to the cover seat. Do not tighten the