13
Press and HOLD the UP button for 5 seconds to enter the programming mode.
OXY3E Programming
Use Up Button to set frequency of backwash cycle. The frequency should never be
less than every 3 days, but may high iron levels or water use may require more
frequent cycles.
Use Up Button to set the hour for time-of-backwash. NOTE: Factory setting is 1:00
AM. If time of backwash is changed ensure that unit does not backwash while
other water treatment equipment may be regenerating.
Use Up Button to set minutes for time-of-backwash.
Use Up Button to set AM or PM for time-of-backwash.
The DEFAULT setting is not used for OXY3E iron filters and must be set to OFF.
Default capacity is 12. This iron filter does not meter the water use.
Adjusting the grain capacity setting will have no effect on
frequency of regeneration or water quality.
Use Up Button to set length of BACKWASH cycle. (factory set for 8 minutes)
Use Up Button to set length of air DRAW cycle. (factory set for 14 minutes)
Use Up Button to set length of FAST RINSE cycle. (factory set for 8 minutes)
The BRINE REFILL cycle is not used for OXY3E iron filters and must be set to OFF.