10.
When adjustment is complete, tighten the lock nuts on the
adjustment screws.
11.
Torque the bed knife
and bed knife shield
bolts to 95 lbs./ft.
(13 Kgm., 128 Nm) using a torque wrench.
12.
Repeat the steps 4-11 to adjust the rear (or down stroke) bed
knife. Turn the rotor slowly for one complete revolution,
checking the exact distance between all the rotary knives and
the bed knives.
13.
Close the hopper and replace the screen and screen cradle,
securing them in place using the swing
bolt
provided.
14.
Close the front and rear doors, and unlock the power or replace
the fuses in the control panel. Turn the disconnect switch to
“ON”.
Figure 13: Inspection of Knives
Bed knife Adjusting Screws
Bed Knife Locking Bolts
Rotor Knife Locking Bolts
6-5
Removing and Replacing Bed Knives
NOTE: This procedure should be performed by a qualified
operator / maintenance mechanic. Protective gloves must be
worn to avoid injury when handling the cutting knives.
To remove and replace bed knives, complete the following
procedure:
1.
Open the granulator by following Steps 1-0 in Section 6-3.
2.
Open the rear-closing panel by releasing the locking latch.
Page 36 of 54
Summary of Contents for BP810
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ......
Page 7: ......
Page 18: ......
Page 20: ......
Page 40: ......
Page 44: ......
Page 45: ...Figure 16 Cutting Chamber Vertical Cross Section DRAWING CA039060S2 Page 45 of 54...
Page 46: ...Figure 17 Cutting Chamber Longitudal Cross Section DRAWING CA039060S1 Page 46 of 54...
Page 47: ...Figure 18 Cutting Chamber Front View DRAWING CA039060S3 Page 47 of 54...
Page 48: ...Figure 19 Cutting Chamber Rear View DRAWING CA039060S4 Page 48 of 54...
Page 49: ...9 Typical Wiring Diagram Page 49 of 54...
Page 50: ...DRAWING D05991100000 Page 50 of 54...
Page 51: ......
Page 53: ......
Page 54: ......