5-2 Identifying M2B Controller Panel Components
Screen Displays
SET POINT Numeric LED
During normal operation, the
SET POINT
LED on the controller
displays the process set point you want the unit to maintain. It also
displays parameter and pre-set function values during setup.
PROCESS Numeric LED
During normal operation, the
PROCESS
LED on the controller
displays the actual process temperature at the To Process
thermocouple. It also lists parameter symbols during setup and
error messages if an error occurs.
Status Indicators
RUN Indicator
The
RUN
indicator is on during normal operation and flashes
during the auto-tuning sequence.
HI HEAT Indicator
The
HI HEAT
indicator is on when fluid heaters are at 100%
capacity to rapidly raise fluid temperature.
LO HEAT Indicator
The
LO HEAT
indicator is on when fluid heaters are at 50 percent
capacity.
COOL Indicator
The
COOL
indicator is on when fluid temperature is above the set
point and is being cooled.
Display Indicators
TO PROCESS Indicator
The
TO PROCESS
indicator is on when the
PROCESS
LED
screen on the controller displays the temperature of the outgoing
fluid.
Summary of Contents for 6017 Series
Page 29: ...Page 28 6017 Series Hot Oil Large Temperature Control Units Notes ...
Page 34: ...6017 Series Hot Oil Large Temperature Control Units Page 33 Notes ...
Page 46: ...6017 Series Hot Oil Large Temperature Control Units Page 45 Notes ...
Page 52: ...6017 Series Hot Oil Large Temperature Control Units Page 51 ...
Page 55: ...Page 54 6017 Series Hot Oil Large Temperature Control Units Service Notes ...
Page 56: ...6017 Series Hot Oil Large Temperature Control Units Page 55 Service Notes ...
Page 57: ...Page 56 6017 Series Hot Oil Large Temperature Control Units Service Notes ...