10
11
PHASE 3: CARTRIDGES
• Remove the yellow cap from the top of the cartridges and write the date with a permanent marker.
• Start by inserting the cartridges from left to right beginning with Stage 1.
Please note there are two Stage 4 Cartridges. They will both be positioned interchangeably in ports 4 and 5.
• Once all cartridges are installed, remove the brine plug from the bottom of the Stage 3 Cartridge.
• Insert the white brine tube into the bottom of Stage 3.
• Mount the Blank Cartridge clip on the wall near the system and place the Blank Cartridge in the clip. (Bag E)
Please note the Blank Cartridge is essential for trouble shooting possible blockages inside the system.
PHASE 4: SOURCE WATER AND TUBING
Ensure the source water to the Sterisil
®
System G5 remains closed until the procedure calls for it to be turned on.
SOURCE WATER CONNECTION - (BAG D)
Supply Tee
• Turn off the water on the municipal supply line. For now the main valve will remained closed.
• Remove the existing hose, wrap the threads with thread tape, and install the supply tee on the cold water
supply. Tighten the tee with a wrench. Hot water should not be used to feed the system.
TUBING CONNECTIONS
To make a connection with quick connect fittings, you will simply push the tubing into the fitting until it stops.
When making cuts, be sure to cut at a right angle to the tubing itself, and inspect the ends for burrs. Be sure to
factor any movement in the system into the tubing length so as to not put tension on ports or components.
Source water (Supply Tee to Source Port)
(Red fitting collar):
OPTIONAL ADD-ONS: Booster Pump and Pre-filter Kit, see
page 14.
• Insert the white 1/4” tubing into the supply tee. The other end
of this tubing will run to the “SOURCE” port on the side of the
system.
• Cut and install the Single Check Valve (SCV) on this line. (Bag
D)
• Cut and install a 1/4” inline ball valve.
Dental Port
(Blue fitting indicator):
• Run a 1/4” line from the blue “DENTAL” port to the chrome
Dental Water Faucet.
• Direct Feed System: Run a 1/4” line from the blue “DENTAL”
port on the system to the customer supplied dental water
supply line that connects to the dental chairs.
D Tank Port
(Blue fitting Indicator):
• Run 1/4” tubing from the blue “DENTAL” port on the system to the 1/4” Tank Ball Valve on the smaller dental
water storage tank.
Autoclave Port
(Green fitting indicator):
OPTIONAL ADD ON:
Sterisil
®
Wand, see page 14.
• Run 1/4” tubing from the green “AUTOCLAVE” port on the system to the white Autoclave Faucet.
Drain Port
(Black fitting indicator):
(Bag D)
• Run a 1/4” line from the black “DRAIN” port to the Drain Saddle
Valve (DSV).
• Note: If you have a floor drain that is accessible you can
always run tubing straight from the black “DRAIN” port on
the system to the floor drain. If not, you will need to install the
drain saddle valve on an existing drain pipe.
Drain saddle valve:
• Start by marking the drain pipe where you intend to drill your 1/4”
hole. The DSV will need to be before or after the peatrap.
• Attach the gasket and mount the saddle valve with the provided
nuts and bolts to the drain pipe.
• Once the DSV is properly mounted remove the gray collet from
the hole.
• Drill through the hole into the drain pipe.
• When you drill the hole, be sure not to drill through the other side
of the drain pipe.
• Clear any metal shavings from the hole, then reinsert the collet.
• Run 1/4” line from the black “DRAIN” port on the system to the DSV.
RO Tank Port
(Yellow fitting indicator):
• Run a 3/8” line from the yellow “RO TANK” port on the system to the 3/8” Tank Ball Valve on the RO Water
Storage Tank.
RO port
(Yellow fitting indicator):
• If no auxiliary RO water will be used then this yellow RO port should remain plugged.
PHASE 5: POWERING UP, PROGRAMMING THE TOUCHSCREEN, AND FILLING THE
TANKS
POWERING UP
Plug in the G5. The touchscreen will power on, and you will be brought to the home screen.
PROGRAMING THE TOUCHSCREEN
(All programing steps below are represented in the installation
video at sterisil.com/sterisil-system-g5.)
• Bring up the details view by touching either the desired Stage
number from the “Home” screen or select the “Stages” tab from
the bottom row.
• Stage 1’s lifespan is for 364 days. If the counter is not reading
364 days you will select “Replace component,” select Stage 1
from the drop-down menu and hit replace.
• Stage 2’s lifespan is based on liters processed and is effective
up to 9,463L. If the counter is not reading 9,463L, you will select
“Replace component,” select Stage 2 from the drop-down menu
and hit replace.