NOTE: To prevent electrical shock and / or damage to the equipment, disconnect the circuits and
discharge the capacitors with high voltage before making diode measurements
1. Connect the black test lead to the "COM" connector and the red test lead to the "V Hz" connector.
2. Set the dial to " ", then press "SELECT" to select Audible or Diode continuity measurement.
3. On it diode test, connect the tips on the diode to measure, the display will show the voltage.
4. On the audible continuity test, connect the test leads at both points of the circuit, if the resistance is
less than 100 a continuous tone will be heard.
Audible continuity and diode tests