background image

ENGLISH

ENGLISH-2

Before using your new Analog Multimeter, please read this 
instruction manual to prevent any damage. Put it away in a 
safe place for future references.

INSTRUCTIONS

Checking the tester circuit, voltage meter, current meter, 
resistance meter, etc. The multimeter with part number MUL-105 
it’s –for many reasons- a high quality device, lightweight, and 
portable. Can be use it for professionals or amateurs.

MAIN CHARACTERISTICS

1.- Audible continuity and battery tester.
2.- Capacity equivalent to a bigger device, with an excellent 
resolution factor of 0,2mV and wide resistance range for 
readings from 0,2 

Ω

 to 20M

Ω

.

3.- 9V and 1,5V internal battery (2xAA)
4.- Easy control, ranges arranged by function.
5.- Make sure the testing points and the measuring terminals are 
adequate for the different purposes.

HOW TO USE THE METER

When you use this meter, pay attention to polarity. The red 
testing point must be connected to positive (+) and the black 
testing point should be connected to negative (-).
When the voltage or current value to be measured is unknown, 
set the dial to the maximum setting. Reduce level by level until 
reaching the desired level.
For accurate readings, search the scale from the point where 
the arrow is aligned with the maximum scale, in order to avoid a 
mistake.

CALIBRATION

To set the ohm range to zero, 

fi

 rst locate the middle button 

(screw type) and with a screwdriver try to place the arrow from 
the panel to zero (in the left side) then, you will 

fi

 nd a knob in the 

left side, plug the black and red testing points, put the banana 
connectors together, in the Rx10 range you will see the arrow 
moves to the right, use the left knob to move the arrow to zero in 
the 

fi

 rst ohm range.

Before using your new Analog Multimeter, please read this
instruction manual to prevent any damage. Put it away in a
safe place for future references.

Summary of Contents for MUL-105

Page 1: ......

Page 2: ...ER When you use this meter pay attention to polarity The red testing point must be connected to positive and the black testing point should be connected to negative When the voltage or current value t...

Page 3: ...Sensitivity 250mV RESISTANCE Ranges x1 0 2 up to 2K medium range 20 x10 2 up to 20K medium range 200 x100 20 up to 200K medium range 2K x1K 200 up to 2M medium range 20K x10 2K up to 20M medium range...

Page 4: ...4 The voltage will appear on the LCD screen Please refers to next table MEASURING AC VOLTAGE 1 Connect the red testing point to the jack signaled VmA and the black testing point to the jack signaled...

Page 5: ...AC setting 3 Connect the testing points to the circuit to be measured and read the dB value BATTERY TEST 1 Connect the red testing point to the jack signaled VmA and the black testing point to the jac...

Page 6: ...over on your multimeter The fuse rarely needs to be replaced and when it does it is usually due to an error in operation If BAT appears on your LCD screen the battery needs to be replaced To replace t...

Page 7: ......

Page 8: ...ol se opera con una mano rangos ordenados de manera funcional 5 Aseg rese de que las terminales de medici n y puntas de prueba sean las adecuadas TIPS PARA USAR TU MULTIMETRO Cuando use ste mult metro...

Page 9: ...50 250 y 1000V Exactitud a escala completa 3 Sensibilidad 10K V CD 25 50V VOLTAJE DE CA Rangos 10 50 250 1000V Exactitud a escala completa 4 Sensibilidad 4K V DECIBELIMETRO 10 a 22dB 0dB 1mW 600 CORR...

Page 10: ...el rango de V CD 3 Conecte la punta de prueba roja a la polaridad positiva y la negra a la negativa 4 Lea el voltaje CD en la escala y aux liese con la siguiente tabla PRUEBA DE VOLTAJE CA 1 Inserte...

Page 11: ...a roja dentro del borne VmA 2 Coloque el selector en la posici n de 10 V CA V 3 Conecte las puntas al circuito a probar y lea en la escala roja de dB PRUEBA DE BATERIA 1 Inserte la punta de prueba neg...

Page 12: ...su mult metro 1 Retire los tornillos de la tapa del mult metro y localice los fusibles 0 5A 250V y 10A 250V respectivamente retire el da ado y reempl celo con uno del mismo valor 2 Tape su mult metro...

Page 13: ...es to costumer as well as warranty service at any of the addresses mentioned later THIS WARRANTY IS VOID IN THE NEXT CASES If the product has been damaged by an accident acts of God mishandling leaky...

Page 14: ...EFECTIVA EN LOS SIGUIENTES CASOS 1 Cuando el producto ha sido utilizado en condiciones distintas a las normales 2 Cuando el producto no ha sido operado de acuerdo con el instructivo de uso 3 Cuando e...

Reviews: