14
Next, draw a box with the measurement of your object width (X value) and length (Y value) and add 15mm on
each value for safe enclosure of the scan. Center this box in your work area.
Make a 2D profile tool path of this box. You can select any end mill setting since we are not actually cutting. Also
set your spindle speed to zero to prevent the spindle from turning on. This tool path is used by the AutolovelerCA
plugin defining the area that the Touch Probe will operate to generate the matrix probe points. It will scan
everything inside the box. After calculating the tool path, save the file to your computer’s desktop (or in a location
that will be easy to find)
Not setting the spindle speed to zero can cause severe damage to the Touch Probe or
personal injury
SETTING THE TOUCH PROBE POSITION FOR SCANNING
Mount the Touch Probe on the machine with one of the methods described previously.
Open UCCNC with the “SC2-XXX 3D Probe” Profile already installed on your machine. Minimize or send the
AutolevelerCA plugin window to the background by clicking anywhere in the UCCNC window.
Next, move the probe to the lowest part of your object and probe the bottom edge of it
, the machine will zero
the Y-axis coordinate.