20
A100K11311
Pulse Technical Manual
●
Under
Gateways
set the following values:
-
Directory Number:
0
-
Name: <name of your choice>
-
Profile:
Gateway
(Gateway option will only be available if there is a
valid license installed)
● Click
Add
followed by
Save
L
Directory Number 0 is optional as you can use any number to
make external calls through the Gateway.
3.8.3 Access Restrictions
Access restrictions are set in the
Station Profiles
menu in the Pulse
Server station:
●
Select
Server
Management
>
Station
Profiles
3.8.4
Configure Telephone Gateway
Log into the Telephone Gateway to register it to the Pulse Server by
using the SIP Gateway Account created in section 3.8.2.
3.8.5 Troubleshooting
When dialling the gateway access number (e.g.
0
), the station display
may show one of the following error messages:
Forbidden
The station is restricted to call via the gateway due to Station Profiles
settings. In the Pulse Server station:
●
Select
Server
Management
>
Station
Profiles
●
Enable the station to call the Gateway.
Error code 488
This is most likely due to a codec mismatch. Check that the codec in the
SIP gateway is set to
G.711U-law
.
Disconnected. No number 0
● The SIP Gateway is not registered to the Pulse Server station. The
SIP Gateway registration can be verified via the Pulse Server:
-Select
Server Management
>
Server Monitoring
-The SIP Gateway should be displayed and have status
Registered
. If it has status
Not Registered
, check the setup of the
SIP gateway.
● The gateway is an AudioCodes MP114/118 and the telephone line is
not connected to the gateway