● If the stations are using static IP addresses, you need to set the
Gateway address for all stations. Log into the Pulse Server, go
to
Main Settings
and set the Gateway address to be the Pulse
Server IP Address (unless you have a real gateway). Go to
Server
Management
>
Server Configuration
, click
Save
then
Apply
. Now
all stations should have a gateway address.
● The network switch may be dropping multicast packets (For
example, Linksys ‘business series’ switches drop all multicast
packets with default configuration). If this is the problem, check the
manual for the network switch.
3.6
Configure Ringlist
Log on to the web interface of the station that will be making the call to
configure the ringlist of the stations that should be called.
To configure a ringlist:
●
Select
SIP Configuration
>
Direct Access Key Settings
There are variants of ringlists that can be set such as ringing time
intervals, loopback, and ringing together with previous stations.
3.6.1 Ringlist with Ringing Time Intervals
The above example ringlist settings may be illustrated as follows: