background image

SVP SERIES PUMP TUBE REPLACEMENT

NOTICE: 

Before installing or servicing the pump, read the pump manual for all safety information and complete instructions. The pump is

designed for installation and service by properly trained personnel.

Pumps with 

QuickPro

Pump Head Manufactured After April 29, 2011

I

PREPARATION

Follow all safety precautions prior to tube replacement.

Prior to service, pump water or a compatible buffer solution through the pump and suction and discharge lines
to remove chemical and avoid contact.

II

REMOVE THE PUMP TUBE

Place the pump in manual mode of operation and set display to 50. 

Figure A 

Turn the pump off and unplug 

the power cord.

Depressurize and disconnect the suction and discharge lines.

Open the back and front of the latches on both sides of the head. 

Figure B

Carefully fold latches back to

prevent contact with the cover.
For CE pump only: Remove the safety screw on cover. 

Remove the tube housing cover and flip to use as a tool in the next step. 

Figure C

Align the center of the inverted cover with the center of the roller assembly so that the three holes on the
face of the cover align with the three knurled lugs on the roller assembly. Position the cover feet near the
tube fittings. 

Figure D

NOTE: The roller assembly needs to be collapsed to remove the tube.

Hold the pump securely, use the tube housing cover as a wrench and quickly (snap) rotate the cover
counter-clockwise to collapse the roller assembly. The tube will no longer be pressed against the tube
housing wall. 

Figure E

NOTE: Counter-clockwise is viewed from facing the head of the pump.

Remove and discard the pump tube.

Figure F

Remove the roller assembly and housing. 

Use a non-citrus all-purpose cleaner to clean chemical residue from the tube housing, roller assembly 
and cover.

Check the housing for cracks. Replace if cracked.

Ensure the rollers turn freely. 

Figure G 

Replace the roller assembly if the rollers are seized or worn or if there is

a reduction or lack of output from the pump.

Reinstall clean tube housing.

Apply AquaShield

®

to the shaft tip.  

Install the roller assembly.

A

B

C

D

E

F

G

PUMP HEAD

PUMP HEAD SERVICE KITS

0-25 psi (0-1.7 bar)

                                                                                                               PART NUMBER         UM

Santoprene

®

Kit includes Santoprene

®

pump tube 

select tube # from 1, 2, 3, 4, 5 for __   

                                                                                                                    

QP25__K   

      KIT

Tygothane

®

Kit includes Tygothane

®*

pump tube 

select tube # from 2, 5 for __                     

                                                                                                                    

QP25T__K   

     KIT

EUROPE

Santoprene

®

Kit includes Santoprene

®

pump tube, ferrules 6 mm  

select tube # from 1, 2, 3, 4, 5 for __                                                           

QP17__K  

       KIT

EUROPE

Tygothane

®*

Kit includes Tygothane

®*

pump tube, ferrules 6 mm

      

select tube # from 2, 5 for __                                                                       

QP69T__K   

     KIT

26-100 psi (1.8-6.9 bar)

                                                                                                               PART NUMBER         UM

Santoprene

®

Kit includes Santoprene

®

pump tube & duckbill 

select tube # from 1, 2, 7 for __

                                                                                                                    

QP10__K   

      KIT

Tygothane

®*

Kit includes #2  Tygothane

®*

pump tube & Pellathane

®*

duckbill              

                                                                                               

QP10T2K

          KIT

EUROPE

Santoprene

®

Kit includes Santoprene

®

pump tube & duckbill, ferrules 6 mm

select tube # from 1, 2, 7 for __                                                                   

QP69__K  

       KIT

EUROPE

Tygothane

®*

Kit includes #2 Tygothane

®*

pump tube, Pellathane

®*

duckbill,

ferrules 6 mm

                                                                                      

QP69T2K   

       KIT

SVP SERIES MANUAL

ADDENDUM

0-25 psi (0-1.7 bar)

                                                                     PART NUMBER         UM       

Includes Santoprene

®

pump tube, ferrules 1/4"  

select tube # from 1, 2, 3, 4, 5 for __

          

QP25__–1  

      EA      

                                                      

QP25__–2

        2-PK

Includes Tygothane

®*

pump tube, ferrules 1/4"  

select tube # from 2, 5 for __

                   

QP25T__–1  

    EA      

EUROPE

Santoprene

®

pump tube, ferrules 6 mm  

select tube # from 1, 2, 3, 4, 5 for __                

QP17__–1        

EA

                                                      

QP17__–2        

2-PK

EUROPE 

Tygothane

®*

pump tube, ferrules 6 mm  

select tube # from 2, 5 for __                           

QP17T__–1       

EA

26-100 psi (1.8-6.9 bar)

                                                                     PART NUMBER         UM       

Includes Santoprene

®

pump tube & duckbill, ferrules 1/4" 

select tube # from 1, 2, 7 for __

               

QP10__–1   

     EA

Includes Tygothane

®* 

#2 pump tube, Pellathane

®* 

duckbill,

ferrules 1/4"                                   

QP10T2–1   

     EA

EUROPE

Santoprene

®

pump tube & duckbill, ferrules 6 mm 

select tube # from 1, 2, 7 for __                       

QP69__–1        

EA

EUROPE

Tygothane

®* 

#2 pump tube, Pellathane

®* 

duckbill,

ferrules 6 mm                                   

QP69T2–1         

EA

*

Tygothane

®

tubes are application specific; confirm chemical compatibility with the chemical resistance guide in the catalog or on the website. In 26-100 psi (1.8-6.9 bar)

applications with a Tygothane

®

tube, a Pellathane

®

duckbill is in the check valve; both materials are clear.

QP SVP Tube Repalcement Addendum 0512_Layout 1  5/31/12  5:05 PM  Page 1

Summary of Contents for SVP Series

Page 1: ...output from the pump Reinstall clean tube housing Apply AquaShield to the shaft tip Install the roller assembly A B C D E F G PUMP HEAD PUMP HEAD SERVICE KITS 0 25 psi 0 1 7 bar PART NUMBER UM Santoprene Kit includes Santoprene pump tube select tube from 1 2 3 4 5 for __ QP25__K KIT Tygothane Kit includes Tygothane pump tube select tube from 2 5 for __ QP25T__K KIT EUROPE Santoprene Kit includes S...

Page 2: ...to the cover lip and then press the latches back to secure Figure Q IV CENTER NEW TUBE Plug the pump in and with the power on and in manual mode set the display to 00 Lift the latch located between the tube fittings leaving the end of the latch engaged with the lip on the tube housing cover Leave the latch on the opposite side engaged Figure R S Depress the prime button and turn the tube fitting o...

Page 3: ... DEL CABEZAL 0 25 psi 0 1 7 bar NO DE PARTE UM Kit de Santoprene incluye tubo de Santoprene seleccione no de tubo 1 2 3 4 5 y complete el no de parte QP25__K KIT Kit de Tygothane incluye tubo de Tygothane seleccione no de tubo 2 5 y complete el no de parte QP25T__K KIT EUROPA Kit de Santoprene incluye tubo de Santoprene y casquillos de 6 mm seleccione no de tubo 1 2 3 4 5 y complete el no de parte...

Page 4: ...EL TUBO Con el dosificador prendido y en modo manual coloque el porcentaje de caudal en 00 Levante la parte trasera del sujetador que se encuentra entre las conexiones del tubo dejando el extremo delantero enganchado en la tapa de la carcasa Deje el otro sujetador completamente cerrado Ilustración R S Presione el botón de cebado y gire la conexión de tubo del lado de succión hacia donde deba mover...