background image

III

INSTALL THE PUMP TUBE AND EXPAND THE ROLLER ASSEMBLY

IMPORTANT! DO NOT lubricate pump tube or roller assembly.

With the power on and in manual mode, verify that the setting is 50. 

Figure H

Turn off the pump and unplug

the power cord.

Place the new tube in the pump head, use your fingers to ensure that it centered over the rollers. 

Figure I

Place the tube housing cover on the tube housing, affix the front of the latches to the cover lip and then press
the latches to secure. 

Figure J

With the cover latched, plug the pump in and turn the pump on. Allow the pump to run the roller assembly in
its collapsed position for one minute to relax the tube.

Figure K

Turn the pump off and unplug the power cord. 

Remove the tube housing cover and flip to use as a tool in the next step. 

Figure L

Align the center of the inverted cover with the center of the roller assembly so that the three holes on the
face of the cover align with the three knurled lugs on the roller assembly. Position the cover feet near the
bottom. 

Figure M

NOTE: The roller assembly needs to be expanded to the tube is pressed against the tube housing wall.   

Hold the pump securely. Use the cover as a wrench and quickly (snap) rotate the roller assembly clockwise to
expand the roller assembly. The tube will be pressed against the tube housing wall. 

Figure N & O

NOTE: Clockwise is viewed from facing the head of the pump.

Apply a small amount of AquaShield

®

to the cover bushing ONLY. DO NOT lubricate the pump tube. 

Figure P

Place the tube housing cover (feet first) on the tube housing, affix the front of the latches to the cover lip and
then press the latches back to secure. 

Figure Q

IV

CENTER NEW TUBE

Plug the pump in and with the power on and in manual mode, set the display to 00. Lift the latch located
between the tube fittings, leaving the end of the latch engaged with the lip on the tube housing cover. Leave
the latch on the opposite side engaged. 

Figure R & S

Depress the prime button and turn the tube fitting on the suction side not more than 1/8 of a turn in the
direction the tube must move. 

Figure T & U

DO NOT let go of the fitting until the tube rides approximately in center of the rollers. 

Release the prime button, let go of the fitting, and secure the latch between the fittings. 

Figure V

For CE pump only: Reinstall the safety screw on the cover.

Inspect the suction and discharge lines, point of injection, and check valve duckbill for blockages. Clean and/or
replace as required.

Reconnect the suction and discharge lines. 

Turn the pump on and run for one minute to verify operation.

Stenner Pump Company
3174 DeSalvo Road
Jacksonville, Florida 32246 USA

Phone               904.641.1666
US Toll Free        800.683.2378
Fax                    904.642.1012

www.stenner.com
[email protected]

© Stenner Pump Company  All Rights Reserved

Tube Housing

Roller Assembly

Tube Housing Cover

Pump Tube

PUMP HEAD EXPLODED VIEW

                                                                                                                              PART NUMBER         UM

Tube Housing (includes latches)                                                    

QP400-1

          EA

                                                                                                  

QP400-2

          2-PK

Roller Assembly                                                                           

QP500-1 

         EA

                                                                                                  

QP500-4

          4-PK

Roller Arm assembly (includes arms, bushings, rollers, screws)      

 

 

QP501-3

         EA

Tube Housing Cover with bushing                                                   

QP100-1 

         EA

                                                                                                  

QP100-4

          4-PK

Latches                                                                                       

QP401-2

          2-PK

Latches

H

I

J

K

L

M

N

O

P

Q

R

S

V

T

U

IMSVPA Rev0612

This information is not intended for specific application purposes. Stenner Pump Company reserves the right to make changes to prices, products, and specifications at any time without prior notice.

Summary of Contents for SVP Series

Page 1: ...output from the pump Reinstall clean tube housing Apply AquaShield to the shaft tip Install the roller assembly A B C D E F G PUMP HEAD PUMP HEAD SERVICE KITS 0 25 psi 0 1 7 bar PART NUMBER UM Santoprene Kit includes Santoprene pump tube select tube from 1 2 3 4 5 for __ QP25__K KIT Tygothane Kit includes Tygothane pump tube select tube from 2 5 for __ QP25T__K KIT EUROPE Santoprene Kit includes S...

Page 2: ...to the cover lip and then press the latches back to secure Figure Q IV CENTER NEW TUBE Plug the pump in and with the power on and in manual mode set the display to 00 Lift the latch located between the tube fittings leaving the end of the latch engaged with the lip on the tube housing cover Leave the latch on the opposite side engaged Figure R S Depress the prime button and turn the tube fitting o...

Page 3: ... DEL CABEZAL 0 25 psi 0 1 7 bar NO DE PARTE UM Kit de Santoprene incluye tubo de Santoprene seleccione no de tubo 1 2 3 4 5 y complete el no de parte QP25__K KIT Kit de Tygothane incluye tubo de Tygothane seleccione no de tubo 2 5 y complete el no de parte QP25T__K KIT EUROPA Kit de Santoprene incluye tubo de Santoprene y casquillos de 6 mm seleccione no de tubo 1 2 3 4 5 y complete el no de parte...

Page 4: ...EL TUBO Con el dosificador prendido y en modo manual coloque el porcentaje de caudal en 00 Levante la parte trasera del sujetador que se encuentra entre las conexiones del tubo dejando el extremo delantero enganchado en la tapa de la carcasa Deje el otro sujetador completamente cerrado Ilustración R S Presione el botón de cebado y gire la conexión de tubo del lado de succión hacia donde deba mover...

Reviews: