APPROXIMATE MAXIMUM OUTPUT@ 50/60Hz
OUTPUT AND SIZING CHARTS
OUTPUTS
MODEL
MAXIMUM
PUMP TUBE
Gallons
Liters
Gallons
Liters
Ounces
Milliliters
PRESSURE
NUMBER
per Day per Day
per Hour
per Hour
per Minute per Minute
M05
25 psi (1.7 bar)
#5
95.0
359.6
3.96
14.98
8.44
249.73
M07
*
100 psi (6.9 bar)
#7
40.0
151.4
1.67
6.31
3.55
105.14
NOTICE:
The information within these charts is solely intended for use as a guide. The output data is an approximation based
on pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
SIZING FOR 1:128 DOSING
MODEL
MAXIMUM
PUMP TUBE
Max. Output @ 50/60 Hz
Max. System Water Flow for 1:128 Dosing
PRESSURE
NUMBER
oz/min
ml/min
gal/min
L/min
M05
25 psi (1.7 bar)
#5
8.4
249.7
8.4
31.8
M07
*
100 psi (6.9 bar)
#7
3.5
105.1
3.5
13.2
NOTE: To inject at a ratio of 1:128 at flow rates higher that 3.5 gpm up to 100 psi, the injection point can be installed
after a pressure regulator. This will allow flow rates up to 8.4 gpm up to 25 psi.
DOSAGE
DOSAGE
MAX. SYSTEM WATER FLOW
PULSE SETTING
OZ/GAL
RATIO
gal/min
1.0
1:128
3.5
1
0.50
1:256
7.0
2
0.25
1:512
14.0
4
ALTERNATIVE SIZING FOR M07 MODEL USING 1 PULSE/GALLON METER
NOTE: 1oz = 29.57 ml; 1 gallon = 3.78 liters
*
Injection check valve included with pumps rated 26-100 psi (1.8-6.9 bar).