www.stenner.com
8
ADJUSTABLE OUTPUT – APPROXIMATE GPD @ 60Hz
OUTPUTS 45 SERIES
MODEL
MAXIMUM
PUMP TUBE
FEED RATE CONTROL SETTING
PRESSURE
NUMBER
L
1
2
3
4
5
6
7
8
9
10
45MHP2*
100 psi (6.9 bar)
#1
0.2
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
45M1
25 psi (1.7 bar)
45MHP10* 100 psi (6.9 bar)
#2
0.5
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
45M2
25 psi (1.7 bar)
45MHP22* 100 psi (6.9 bar)
#7
1.1
2.2
4.4
6.6
8.8
11.0 13.2 15.4 17.6 19.8 22.0
45M3
25 psi (1.7 bar)
#3
45M4
25 psi (1.7 bar)
#4
1.7
3.5
7.0 10.5 14.0 17.5 21.0 24.5 28.0 31.5 35.0
45M5
25 psi (1.7 bar)
#5
2.5
5.0
10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0
MODEL
MAXIMUM
PUMP TUBE
FEED RATE CONTROL SETTING
PRESSURE
NUMBER
L
1
2
3
4
5
6
7
8
9
10
45MHP2*
100 psi (6.9 bar)
#1
0.6
0.9
1.8
2.7
3.6
4.5
5.5
6.4
7.3
8.2
9.1
45M1
25 psi (1.7 bar)
45MHP10* 100 psi (6.9 bar)
#2
1.5
3.0
6.1
9.1
12.1 15.1 18.2 21.2 24.2 27.3 30.3
45M2
25 psi (1.7 bar)
45MHP22* 100 psi (6.9 bar)
#7
3.3
6.6
13.3 20.0 26.6 33.3 40.0 46.6 53.3 60.0 66.6
45M3
25 psi (1.7 bar)
#3
45M4
25 psi (1.7 bar)
#4
5.1
10.6 21.2 31.8 42.4 53.0 63.6 74.2 84.8 95.4 106.0
45M5
25 psi (1.7 bar)
#5
7.6
15.1 30.3 45.4 60.6 75.7 90.8 106.0 121.1 136.3 151.4
ADJUSTABLE OUTPUT – APPROXIMATE LPD @ 50Hz
FIXED OUTPUT
MODEL
MAXIMUM
PUMP TUBE
GPD 60Hz
LPD 50Hz
PRESSURE
NUMBER
45MPHP2*
100 psi (6.9 bar)
#1
3.0
9.1
45MP1
25 psi (1.7 bar)
45MPHP10* 100 psi (6.9 bar)
#2
10.0
30.3
45MP2
25 psi (1.7 bar)
45MPHP22* 100 psi (6.9 bar)
#7
22.0
66.6
45MP3
25 psi (1.7 bar)
#3
45MP4
25 psi (1.7 bar)
#4
35.0
106.0
45MP5
25 psi (1.7 bar)
#5
50.0
151.4
NOTICE:
The information within this chart is solely intended for use as a guide. The output data is an approximation based on
pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
*
Injection check valve is included with pump rated 26-100 psi (1.8-6.9 bar).