API A065 series Interfacing Via bowling (MC2)/Switch pinsetters
17
DISTANCE FOR SPEED [LEFT - RIGHT LANE]
Clearance in centimeters between Speed and Start photocell. Default value 23 CM.
PIN READ DELAY [LEFT-RIGHT LANE]
Delay for scan the pins after ball passes trough the start photocell. Time is in seconds; do not
exceed 2.8 seconds or the pinsetter will not execute correctly the Strike and Gutter cycle
Note: The
PIN READ DELAY
could be adjusted as need, it’s important scan the pins when they are
standing correctly on deck, before pinsetter table run.
START DISTANCE
Clearance, in centimeters, between Steltronic trigger sensor and last row of pins. The default value
is 396. Change this parameter (increasing the value) when the Sciba is installed with the extra
support for rise the Bumpers because photocells will see only a “cord” when the ball pass trough.
OFF DELAY
Timeout in second for switch off the pinsetter after the end of the game.
NOTAP+10FRAME RESPOT
For automatic 10
th
frame reset: the selection is
MODIFIED CYCLE:
pinsetter will receive a fake fast
strike pulse.
1 CAMERA PER LANE
Selection for ODD or Multiple Sciba. Tag the checkbox only if necessary. When a single camera or 2
camera for 2 lanes are installed, tag the checkbox 1
CAMERA PER LANE
and set the selection
referring to the next samples:
ODD LANE
EVEN LANE
LEFT SCIBA = STANDARD
RIGHT SCIBA = STANDARD
ODD LANE
EVEN LANE
LEFT SCIBA = CROSSED
RIGHT SCIBA = STANDARD
ODD LANE
EVEN LANE
LEFT SCIBA = STANDARD
RIGHT SCIBA = CROSSED
ODD LANE
EVEN LANE
LEFT SCIBA = CROSSED
RIGHT SCIBA = CROSSED
LEFT SCIBA = STANDARD
RIGHT SCIBA = NONE
LEFT SCIBA = CROSSED
RIGHT SCIBA = NONE