API A065 series Interfacing Via bowling (MC2)/Switch pinsetters
10
STELTRONIC HIGH VOLTAGE BOX [H.V.B]
The Bumpers with Toggle + UP/DOWN Switch need a High Voltage box to be drive by Scoring.
Steltronic developed an High voltage box (H.V.B.) ready to be used for bumpers, Glow light,
Maintenance call. Max current for external devices: 10 A. The HVB must be specifically ordered for
the right AC input: 110/220/240 VAC. VDE plug or cable are not included and need to be ordered
separately.
Steltronic HVB
HVB connection for Bumpers with UP –DOWN Switch
Connect the UP and DOWN motor and the Up and down Switch.
HVB connection for driving White and glow pinsetter light
Short the Up switch (pin 6 and 5) .
Short the Down switch (pin 4 and 3).
Connect the AC power to the pinsetter using the pinsetter AC output for standard white light.
Connect the GLOW light to UP MOTOR output.
Connect the WHITE light to the DOWN MOTOR output.
HVB for driving Bar Call, mechanic calls AC high voltage lamps
Short the Up switch (pin 6 and 5) .
Short the Down switch (pin 4 and 3).
Connect the AC power to the standard plug.
Connect the LAMP using the UP MOTOR output.