INS_GALAXY SERIES_BY REV C

9 - GALAXY - FACTORY WIRING

TIMER RELA

Y SE

TTINGS

To

 light the fireplace: 

Activate the switch. 

The fireplace has a pre and post timer

, set at the factory for 30 seconds. 

 

The powervent and flame will not turn on for 30-60 seconds after  switch is activated and the powervent will run for 30 seconds after 

it has been shut off.

 

B. FIELD WIRING (SERVICE & TROUBLESHOOTING)

Figure 9B

Summary of Contents for 4-BY-2-GL

Page 1: ...y electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call t...

Page 2: ...INS_GALAXY SERIES_BY REV C Page 2...

Page 3: ...izontal Cap Location Clearances 16 17 F Vertical Cap Location Clearances 18 G Roof Termination Cap Installation 19 H Wall Termination Cap Installation 20 I Outside Air Intake 21 J Changing Outside Air...

Page 4: ...ian Safe T Touch units only Clean glass only when cool and only with non abrasive cleansers Safe T Touch units only Do not operate this appliance with the glass frame assembly removed cracked or broke...

Page 5: ...OA A B C D E F G H I 4 BY 2 GL 8 10 48 25 32 1 239 24 610 24 610 18 9 16 471 53 3 4 1 365 26 7 8 683 24 610 42 1 067 50 1 270 5 BY 2 GL 8 10 60 25 32 1 544 24 610 24 610 18 9 16 471 65 3 4 1 670 32 7...

Page 6: ...D ON THE FACE OF THE FIREPLACE BELOW THE BOTTOM VIEWING EDGE ONLY 1 25 6 152 Figure 2B WARNING NON COMBUSTIBLE ZONE USE ONLY NON COMBUSTIBLE MATERIAL IN THIS AREA FOR ENTIRE WIDTH OF FIREPLACE DO NOT...

Page 7: ...7 Complete electrical hook up 8 Complete venting installation 9 Install facing material mantel or cabinetry 10 Install logs or glass and ember material or media 11 Verify proper operation of fireplace...

Page 8: ...EPLACE IS NOT LOAD BEARING NOTE OTHER CLEARANCES APPLY ALL CLEARANCES MUST BE MAINTAINED A STANDOFF INSTALLATION STEP 1 Locate the standoffs on top of the fireplace Standoffs STEP 2 Remove the screws...

Page 9: ...in manual bag with each fireplace Nailing tabs mount here for single sided see through and pier fireplaces STEP 1 Remove two screws Place nailing tabs and replace the two screws STEP 2 Fold out small...

Page 10: ...EARANCE TO THE B VENT MUST BE MAINTAINED 4 FRAMING FLUE B VENT J J K K FLUE B VENT J L K J L K 6 A C B NOTE Make sure fireplace is square in both directions prior to finishing it or the glass will not...

Page 11: ...FRAMING NOTE Framing dimensions should allow for wall covering thickness and fireplace facing materials When using a hearth adjust rough opening size as necessary to maintain at least minimum clearanc...

Page 12: ...E BY A LICENSED OR QUALIFIED SERVICE PERSON WARNING DO NOT REMOVE GLASS ASSEMBLY WHEN HOT NOTE GLASS REMOVAL AND INSTALLATION MUST BE PERFORMED WITH TWO PEOPLE NOTE Glass must be removed using quality...

Page 13: ...igure 6B 3 5 Place the long horizontal trim piece between the lower glass clips Slide back against the vertical trim piece See Figure 6B 3 and Figure 6B 4 Outer Glass Edge Protectors 6 For the panes o...

Page 14: ...r Propane CAUTION Installation of the gas line must only be done by a qualified person in accordance with local building codes if any If not follow ANSI 223 1 NOTE The appliance and its individual shu...

Page 15: ...4 RSIF180 120 5 8 35 Refer to the vent systems manufacturer s installation manual for complete installation instructions Installation must conform with the venting requirements and restrictions as out...

Page 16: ...to prevent condensation on window D Ventilated soffit 24 610 mm E Unventilated soffit 12 305 mm F Outside corner 12 305 mm G Inside corner to non combustibles 12 305 mm H Meter Regulator Not to be ins...

Page 17: ...n combustible I Combustible Non combustible 12 305mm C Clearance from corner in recessed location Combustible 24 609 6mm Non combustible 12 304 8mm D Minimum width for back wall of a recessed location...

Page 18: ...TO 10 12 2 5 0 76 OVER 10 12 TO 11 12 3 25 0 99 OVER 11 12 TO 12 12 4 0 1 22 OVER 12 12 TO 14 12 5 0 1 52 OVER 14 12 TO 16 12 6 0 1 83 OVER 16 12 TO 18 12 7 0 2 13 OVER 18 12 TO 20 12 7 5 2 27 OVER 2...

Page 19: ...G POWERVENT MOUNTING BRACKETS OR DRILL MOUNTING HOLES TO MATCH BASE INSULATION PAD STEEL CHIMNEY ADAPTER POWERVENT MOUNTING BRACKETS OR DRILL MOUNTING HOLES TO MATCH BASE INSULATION PAD MECHANICAL FLU...

Page 20: ...WER VENT DRILL 1 4 HOLES TO MATCH POWER VENT BASE USE APPROPRIATE HEAVY DUTY FASTENERS TO SECURE POWER VENT DRILL 1 4 HOLES TO MATCH POWER VENT BASE ACCESS PANEL NEEDED FOR FUTURE DAMPER SERVICE Wall...

Page 21: ...take connections on the side and the bottom of the fireplace Use chart on Page 15 to determine which size outside metal pipe you should use for your fireplace Connect only to metal intake pipe or Stel...

Page 22: ...4 4 9 7 8 HP 1 10 1 7 1 4 1 2 To light the fireplace Activate the switch The fireplace has a pre and post timer set at the factory for 30 seconds The powervent and flame will not turn on for 30 60 sec...

Page 23: ...ace Activate the switch The fireplace has a pre and post timer set at the factory for 30 seconds The powervent and flame will not turn on for 30 60 seconds after switch is activated and the powervent...

Page 24: ...INS_GALAXY SERIES_BY REV C Page 24 9 GALAXY ELECTRIC Figure 9C 1 Terminals 1 2 C 1 TERMINALS 1 2 LED Lights Figure 9C 2 Terminals 3 4 C 2 TERMINALS 3 4 Main Flame...

Page 25: ...Page 25 INS_GALAXY SERIES_BY REV C 9 GALAXY ELECTRIC Figure 9C 3 Terminals 5 6 C 3 TERMINALS 5 6 Fireplace Power Figure 9C 4 Terminals 7 8 C 4 TERMINALS 7 8 Powervent Connection...

Page 26: ...NS_GALAXY SERIES_BY REV C Page 26 9 GALAXY ELECTRIC NOTE OPTIONAL IF A DAMPER IS NOT USED DO NOT CONNECT ANYTHING TO TERMINALS 9 10 Figure 9C 5 Terminals 9 10 C 5 TERMINALS 9 10 Flue Damper Connection...

Page 27: ...age 27 INS_GALAXY SERIES_BY REV C 9 GALAXY ELECTRIC NOTE OPTIONAL IF A DAMPER IS NOT USED TERMINALS 11 AND 12 HAVE A JUMPER ACROSS THEM Figure 9C 6 Terminals 11 12 C 6 TERMINALS 11 12 Flue Damper Prov...

Page 28: ...non combustible area mentioned in B D Combustible finishing materials allowed E Combustible mantel may be placed above the top of the glass viewing area F Combustible hearth may be placed below the bo...

Page 29: ...liance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water WHAT TO DO IF...

Page 30: ...place on at switch OFF 2 ON 5 Figure 11B 11 LIGHTING SHUTDOWN STOP Read safety information on previous page and front cover of this manual before continuing NOTE This fireplace is equipped with an ign...

Page 31: ...R KIND OF MEDIA WITHOUT WRITTEN APPROVAL OF STELLAR HEARTH PRODUCTS Figure 13 Place the supplied glass media into the base tray Cover the base evenly Do not use more than the supplied amount Do not ge...

Page 32: ...SEE PAGE 15 Valve Honeywell Smart Valve SV9501 Pilot Honeywell Smart Valve Q3450C1185 Vacuum Switch Cleveland Controls AFS 405 Flue Pipe Approved SEE PAGE 15 24vac Transformer Dayton 24vac 40 VA Orif...

Page 33: ...ew home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever o...

Page 34: ...wing Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under...