Stellar
®
108-14-40 Shuttle Owner’s Manual | Page 27
Set System Relief Pressure
1. Engage the PTO. Run the PTO at 1200 RPM.
2. Push the lever labeled ‘lift’ until the boom bottoms out. Keep pushing the lever forward
until the pressure is set.
3. Locate the main relief valve and release the jam nut using a 13 mm wrench:
4. Adjust the system relief pressure using 4 mm allen wrench (See chart on previous page).
Clockwise increases pressure, counter clockwise decreases pressure:
5. Once system pressure is set, tighten the jam nut to lock system pressure. Permanent
thread lock should not be used:
6. Release all functions and disengage the PTO. Snap tamper cap into position over the
jam nut. The break away clip will be destroyed if the cap is removed.
-
+
Summary of Contents for 108-14-40
Page 8: ...Page 2 Stellar 108 14 40 Shuttle Owner s Manual Acceptable Subframe Dimensions Model 108 14 40...
Page 34: ...Page 28 Stellar 108 14 40 Shuttle Owner s Manual This page intentionally left blank...
Page 42: ...Page 36 Stellar 108 14 40 Shuttle Owner s Manual Optional Tab Alarm Wire Harness PN 26291...
Page 44: ...Subject to Change without Notification 2021 Stellar Industries Inc...